Saltar al contenido
Merck

Highly sensitive GC/MS/MS method for quantitation of amino and nonamino organic acids.

Analytical chemistry (2011-03-11)
Hans F N Kvitvang, Trygve Andreassen, Tomas Adam, Silas G Villas-Bôas, Per Bruheim
RESUMEN

Metabolite profiling methods are important tools for measurement of metabolite pools in biological systems. While most metabolite profiling methods report relative intensities or depend on a few internal standards representing all metabolites, the ultimate requirement for a quantitative description of the metabolite pool in biological cells and fluids is absolute concentration determination. We report here a high-throughput and sensitive gas chromatography/tandem mass spectrometry (GC/MS/MS) targeted metabolite profiling method enabling absolute quantification of all detected metabolites. The method is based on methyl chloroformate derivatization and quantification by spiking samples with metabolite standards separately derivatized with deuterated derivatization reagents. The traditional electron impact ionization is replaced with positive chemical ionization since the latter to a much larger extent preserve the molecular ion and other high molecular weight fragments. This made it easier to select unique MS/MS transitions among the many coeluting metabolites. Currently, the novel GC/MS/MS method comprises 67 common primary metabolites of which most belong to the groups of amino and nonamino organic acids. We show the applicability of the method on urine and serum samples. The method is a significant improvement of present methodology for quantitative GC/MS metabolite profiling of amino acids and nonamino organic acids.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Glicina, ReagentPlus®, ≥99% (HPLC)
Sigma-Aldrich
Glicina, suitable for electrophoresis, ≥99%
Sigma-Aldrich
Glicina, BioUltra, for molecular biology, ≥99.0% (NT)
Sigma-Aldrich
Ácido cítrico, meets analytical specification of Ph. Eur., BP, USP, E330, anhydrous, 99.5-100.5% (based on anhydrous substance)
Sigma-Aldrich
L-Leucine, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
L-cisteína, 97%
Sigma-Aldrich
L-Prolina, from non-animal source, meets EP, USP testing specifications, suitable for cell culture
Sigma-Aldrich
L-cisteína, from non-animal source, BioReagent, suitable for cell culture, ≥98%
Sigma-Aldrich
L-Metionina, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 99.0-101.0%
Sigma-Aldrich
L-Lisina, ≥98% (TLC)
Sigma-Aldrich
Adipic acid, 99%
Sigma-Aldrich
Ácido pirúvico, 98%
Sigma-Aldrich
L-Leucine, reagent grade, ≥98% (HPLC)
Sigma-Aldrich
L-Isoleucina, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
L-Serine, ReagentPlus®, ≥99% (HPLC)
Sigma-Aldrich
L-Tirosina, from non-animal source, meets EP, USP testing specifications, suitable for cell culture, 99.0-101.0%
Sigma-Aldrich
Ácido L-aspártico, reagent grade, ≥98% (HPLC)
Sigma-Aldrich
L-Serine, from non-animal source, meets EP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
Ácido L-(+)-Láctico, ≥98%
Sigma-Aldrich
Glicina, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, ≥98.5%
Sigma-Aldrich
L-Alanine, ≥98% (TLC)
Sigma-Aldrich
L-Phenylalanine, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 98.5-101.0%
SAFC
Glicina
Sigma-Aldrich
L-cisteína, BioUltra, ≥98.5% (RT)
Sigma-Aldrich
L-Valine, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
Ferulic acid, 99%
Sigma-Aldrich
L-Threonine, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 99.0-101.0%
SAFC
L-Metionina
Sigma-Aldrich
Methyl chloroformate, 99%
Sigma-Aldrich
Nicotinic acid, ≥99.5% (HPLC)