Saltar al contenido
Merck

Enantiomer separation of alpha-ionone using gas chromatography with cyclodextrin derivatives as chiral stationary phases.

Journal of chromatography. A (2000-02-16)
F Quattrini, G Biressi, M Juza, M Mazzotti, C Fuganti, M Morbidelli
RESUMEN

The gas chromatographic enantiomer separation of alpha-ionone was studied with three different chiral stationary phases using as chiral selectors: (1) heptakis(2,3,6-tri-O-methyl)-beta-cyclodextrin, dissolved in polysiloxane PS-086, (2) octakis(2,6-di-O-pentyl-3-O-trifluoroacetyl)-gamma-cyclodextrin and (3) octakis(2,6-di-O-pentyl-3-O-butanoyl)-gamma-cyclodextrin, both dissolved in polysiloxane SE-54. The influence of the concentration of the chiral selector in the polysiloxane, coated on Chromosorb P AW-DMCS 80-100 mesh, is described and discussed, as well as the effect of Chromosorb loading. The feasibility of the preparative gas chromatographic separation of the enantiomers of alpha-ionone is considered; in order to provide a term of comparison, the estimated performances are compared with those achieved in the separation of the enantiomers of the inhalation anaesthetic enflurane.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
α-Ionone, ≥90%, stabilized
Sigma-Aldrich
α-Ionone, technical grade, 90%