推荐产品
product name
Ascentis® Si HPLC 色谱柱, 5 μm particle size, L × I.D. 25 cm × 2.1 mm
材料
stainless steel column
agency
suitable for USP L3
產品線
Ascentis®
特點
endcapped: no
製造商/商標名
Ascentis®
包裝
1 ea of
參數
≤70 °C temp. range
400 bar pressure (5801 psi)
技術
HPLC: suitable
LC/MS: suitable
長度 × 內徑
25 cm × 2.1 mm
表面積
450 m2/g
雜質
<5 ppm metals
基質
fully porous particle
silica gel high purity, spherical
基質活性組
silica phase
粒徑
5 μm
孔徑
100 Å
工作pH值範圍
2-6
應用
food and beverages
分離技術
hydrophilic interaction (HILIC)
normal phase
正在寻找类似产品? 访问 产品对比指南
一般說明
Ascentis 系列色谱柱是 Supelco 科学家推出的第四代 HPLC 色谱柱技术。Ascentis 系列色谱柱是以高纯硅胶为基质,孔径 100Å,硅胶粒径为 3、5 和 10 微米。该色谱柱用于小分子的应用,柱内径可从微径柱(1.0mm 内径)扩展到制备尺寸(50mm 内径)。该系列包括 C18、C8、苯基、Si 和内嵌极性基团相(反相酰胺)。
Ascentis Si 是具有高载样量和优良峰形的硅胶柱。Ascentis Si 在正相和 HILIC/ANP(水性正相)模式下都可使用。
Ascentis Si 是具有高载样量和优良峰形的硅胶柱。Ascentis Si 在正相和 HILIC/ANP(水性正相)模式下都可使用。
法律資訊
Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany
Analytical chemistry, 80(9), 3285-3290 (2008-03-18)
A new method for the simultaneous determination of ozone and carbonyls in air using a two-bed cartridge system has been developed. Each bed consists of reagent-impregnated silica particles. The first contains trans-1,2-bis-(4-pyridyl) ethylene (BPE) while the second contains 2,4-dinitrophenylhydrazine (DNPH).
Journal of chromatography. A, 1217(1), 65-74 (2009-11-27)
This study investigates lipophilicity determination by chromatographic measurements using the polar embedded Ascentis RP-Amide stationary phase. As a new generation of amide-functionalized silica stationary phase, the Ascentis RP-Amide column is evaluated as a possible substitution to the n-octanol/water partitioning system
Journal of pharmaceutical and biomedical analysis, 50(5), 703-709 (2009-06-30)
The performance of a narrow bore silica based monolith column (5 cm x 2 mm) was compared to 5 cm long narrow bore (internal diameter < or = 2.1 mm) columns, packed with shell particles (2.7 microm) and totally porous
Journal of pharmaceutical and biomedical analysis, 49(1), 64-71 (2008-11-29)
The performance of 5 cm long columns packed with shell particles was compared to totally porous sub-2 microm particles in gradient and isocratic elution separations of hormones (dienogest, finasteride, gestodene, levonorgestrel, estradiol, ethinylestradiol, noretistherone acetate, bicalutamide and tibolone). Peak capacities
Journal of chromatography. A, 1289, 13-18 (2013-04-04)
Two analytical procedures are proposed where HILIC and RPLC techniques are coupled with tandem mass spectrometry detection for rapid determination of trace amounts of nicotine in zero-level liquids for electronic cigarettes. Samples are prepared on the basis of the approach
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门