Skip to Content
Merck

Salt effects in electromembrane extraction.

Journal of chromatography. A (2014-05-06)
Knut Fredrik Seip, Henrik Jensen, Thanh Elisabeth Kieu, Astrid Gjelstad, Stig Pedersen-Bjergaard
ABSTRACT

Electromembrane extraction (EME) was performed on samples containing substantial amounts of NaCl to investigate how the presence of salts affected the recovery, repeatability, and membrane current in the extraction system. A group of 17 non-polar basic drugs with various physical chemical properties were used as model analytes. When EME was performed in a hollow fiber setup with a supported liquid membrane (SLM) comprised of 2-nitrophenyl octyl ether (NPOE), a substantial reduction in recovery was seen for eight of the substances when 2.5% (w/v) NaCl was present. No correlation between this loss and the physical chemical properties of these substances was seen. The recovery loss was hypothesized to be caused by ion pairing in the SLM, and a mathematical model for the extraction recovery in the presence of salts was made according to the experimental observations. Some variations to the EME system reduced this recovery loss, such as changing the SLM solvent from NPOE to 6-undecanone, or by using a different EME setup with more favorable volume ratios. This was in line with the ion pairing hypothesis and the mathematical model. This thorough investigation of how salts affect EME improves the theoretical understanding of the extraction process, and can contribute to the future development and optimization of the technique.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Sodium hydroxide-16O solution, 20 wt. % in H216O, 99.9 atom % 16O
Supelco
Reserpine Standard for LC-MS, analytical standard, for LC-MS
Clomipramine hydrochloride, for microbiological assay, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Potassium sulfate, 99.99% trace metals basis
Sigma-Aldrich
Citalopram hydrobromide, ≥98% (HPLC)
Sigma-Aldrich
Potassium sulfate, BioUltra, ≥99.0% (AT)
Supelco
2-Nitrophenyl octyl ether, Selectophore, ≥99.0%
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
2-Nitrophenyl octyl ether, 99%
Sigma-Aldrich
Pyrilamine maleate salt
Sigma-Aldrich
Potassium sulfate, BioXtra, ≥99.0%
Sigma-Aldrich
Potassium sulfate, suitable for plant cell culture
Sigma-Aldrich
Clomipramine hydrochloride, ≥98% (HPLC), powder
Sigma-Aldrich
Reserpine
USP
Verapamil hydrochloride, United States Pharmacopeia (USP) Reference Standard
Supelco
Pyrilamine maleate, Pharmaceutical Secondary Standard; Certified Reference Material
Reserpine, European Pharmacopoeia (EP) Reference Standard
Mepyramine maleate, European Pharmacopoeia (EP) Reference Standard
USP
Citalopram hydrobromide, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Imidazole buffer Solution, BioUltra, 1 M in H2O
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Formic acid, ACS reagent, ≥88%
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Clemastine fumarate salt, ≥98% (HPLC)
Sigma-Aldrich
Formic acid solution, BioUltra, 1.0 M in H2O
Sigma-Aldrich
Phosphoric acid, crystalline, ≥99.999% trace metals basis
Sigma-Aldrich
Phosphoric acid, ≥85 wt. % in H2O, ≥99.999% trace metals basis
Sigma-Aldrich
Acetonitrile, for HPLC, for UV, ≥99.9% (GC)