- Trapping efficiency of selected adsorbents for various airborne pesticides.
Trapping efficiency of selected adsorbents for various airborne pesticides.
Journal of environmental science and health. Part. B, Pesticides, food contaminants, and agricultural wastes (1991-08-01)
R B Leidy, C G Wright
PMID1787261
ABSTRACT
A study was conducted to compare the efficiency of five adsorbents used by government and private laboratories to collect airborne pesticides. Six pesticides, acephate, chlordane, chlorpyrifos, diazinon, heptachlor, and propoxur, were vaporized in a closed system and collected on each of the adsorbents, Chromosorb 102, ORBO 42, ORBO 44 (chlordane and heptachlor only), polyurethane foam (PUF) or Tenax GC, by drawing 250 L of air through the adsorbent. There were no differences in collection efficiency of the five pesticides on Chromosorb 102, ORBO's 42/44, and PUF. The efficiency with Tenax was somewhat less with several of the pesticides.
MATERIALS
Product Number
Brand
Product Description
Supelco
ORBO™ 609 Amberlite™ XAD®-2 (20/50) 400/200 mg, W,W,W separators, O.D. × L 8 mm × 110 mm, pkg of 50 ea
Supelco
ORBO™ 402 Tenax® TA specially treated (35/60), 100/50 mg, W,W,W separators, O.D. × L 8 mm × 100 mm, pkg of 50 ea
Supelco
ORBO™ 502 Activated Silica Gel (20/45) 100/50 mg, W,W,F separators, O.D. × L 6 mm × 75 mm, pkg of 50 ea
Supelco
ORBO™ 49P (OVS) Supelpak™-20 specially treated Amberlite™ XAD®-2 (20/40), 270/140 mg, RC,GFF,F,F (specially cleaned) separators, O.D. × L 13-8 mm × 75 mm , OSHA Versatile Sampler (OVS) Tube, pkg of 10 ea
Supelco
ORBO™ 53 Activated Silica Gel (20/40) specially cleaned, 400/200 mg with Glass Fiber Filters, GFF,F,F separators, O.D. × L 7 mm × 100 mm, pkg of 50 ea
Supelco
ORBO™ 554 H2SO4 on Silica Gel (20/40) 150/75 mg, W,W,W separators, O.D. × L 6 mm × 75 mm, pkg of 50 ea
Supelco
ORBO™ 23 2-HMP on Amberlite™ XAD®-2 (20/40), 120/60 mg, W,W,W separators, O.D. × L 6 mm × 85 mm, pkg of 25 ea
Supelco
ORBO™ 65P (OVS) Amberlite™ XAD®-4 specially cleaned, 160/80 mg, RC,GFF,F,F (specially cleaned) separators, O.D. × L 13-8 mm × 75 mm , OSHA Versatile Sampler (OVS), pkg of 10 ea
Supelco
ORBO™ 90 Carboxen® 564 (20/45), 160/80 mg, W,F,F separators, O.D. × L 6 mm × 75 mm, pkg of 25 ea, for analyte group MEK (methylethyl ketone)
Supelco
ORBO™ 43 Supelpak™-20 specially treated Amberlite™ XAD®-2 (20/40), 100/50 mg, W,W,W (specially treated) separators, O.D. × L 8 mm × 100 mm, pkg of 50 ea
Supelco
ORBO™ 24 2-HMP on Amberlite™ XAD®-2 (20/40), 150/75 mg, W,W,W separators, O.D. × L 6 mm × 105 mm, pkg of 25 ea
Supelco
ORBO™ 52 Small Activated Silica Gel (20/40) 150/75 mg, pk 50, W,W,F separators, O.D. × L 6 mm × 75 mm, pkg of 50 ea
Supelco
ORBO™ 92 Carboxen® 564 (20/45), 160/80 mg, W,F,F separators, O.D. × L 6 mm × 75 mm, pkg of 25 ea, for analyte group Vinyl acetate