Direkt zum Inhalt
Merck

20811

Supelco

Beschichteter ORBO 80 Filter

with cassettes: no, filter O.D. 37 mm, pkg of 25 ea

Synonym(e):

ORBO 80 Isocyanat-Filter

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
41104900

Materialien

glass fiber filter

Agentur

ASTM® D5836
OSHA 5002

Produktlinie

ORBO

Verpackung

pkg of 25 ea

Hersteller/Markenname

ORBO 80

Methode(n)

active air sampling: suitable

Filter AD

37 mm

Aktive Matrixgruppe

1,2-PP, 1-(2-pyridyl)piperazine

Anwendung(en)

air monitoring
environmental
industrial hygiene

Kompatibilität

for analyte group isocyanate

Lagertemp.

2-8°C

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Der mit 1,2-PP-beschichtete ORBO 80 Filter ist ein mit 1-(2-Pyridyl)-piperazin beschichteter Glasfaserfilter, der optimal für die Probennahme von Diisocyanaten aus der Luft geeignet ist.

Rechtliche Hinweise

ASTM is a registered trademark of American Society for Testing and Materials
ORBO is a trademark of Sigma-Aldrich Co. LLC

Piktogramme

Exclamation mark

Signalwort

Warning

Gefahreneinstufungen

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

Zielorgane

Respiratory system

Lagerklassenschlüssel

10 - Combustible liquids

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Leider sind derzeit keine COAs für dieses Produkt online verfügbar.

Wenn Sie Hilfe benötigen, wenden Sie sich bitte an Kundensupport

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Kunden haben sich ebenfalls angesehen

Slide 1 of 1

1 of 1

Bjørn T Moe et al.
Anticancer research, 29(4), 1047-1052 (2009-05-06)
Endometrial hyperplasia is a precursor lesion of endometrial carcinoma. Clinical studies of endometrial hyperplasia have shown that levonorgestrel (LNG) is more therapeutically effective than medroxyprogesterone acetate (MPA). The present pharmacological in vitro study was performed to compare progestin effects on
K Flo et al.
Scandinavian journal of clinical and laboratory investigation, 55(8), 715-721 (1995-12-01)
Elevated extracellular cGMP levels have been observed in various clinical conditions, and the analyte has been proposed as a diagnostic marker of cardiovascular as well as malignant diseases. However, the use of extracellular cGMP as a pathophysiological marker requires detailed
A Orbo et al.
Tidsskrift for den Norske laegeforening : tidsskrift for praktisk medicin, ny raekke, 117(7), 972-976 (1997-03-10)
The development of female steroid hormone-related neoplasms such as gynaecologic and mammary cancers is influenced by hormones administered exogenously. Hormonal contraceptives and hormone replacement therapy both affect the risk of developing cancers in the endometrium, cervix, ovarium, and mammary glands.
J P Baak et al.
The American journal of surgical pathology, 25(7), 930-935 (2001-06-23)
Prospective multicenter evaluation of the WHO classification and the morphometric D-score to predict endometrial hyperplasia cancer progression. In 132 endometrial hyperplasias WHO classification was performed by two experienced gynecologic pathologists. The D-score was assessed blindly by technicians in a routine
Anne Ørbo et al.
The Journal of steroid biochemistry and molecular biology, 113(1-2), 139-149 (2009-01-14)
Patients with endometrial hyperplasia representing preliminary stages of endometrial cancer have shown to respond to therapy in 100% of the cases when treated with levonorgestrel-impregnated intrauterine device. Anti-proliferative effect has also been reported after application of an anti-progestin impregnated intrauterine

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.