Recommended Products
Assay
98%
SMILES string
[Na+].[O-]C(=O)c1cccnc1
InChI
1S/C6H5NO2.Na/c8-6(9)5-2-1-3-7-4-5;/h1-4H,(H,8,9);/q;+1/p-1
InChI key
KFLRWGSAMLBHBV-UHFFFAOYSA-M
Signal Word
Warning
Hazard Statements
Precautionary Statements
Hazard Classifications
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
Target Organs
Respiratory system
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
Personal Protective Equipment
dust mask type N95 (US), Eyeshields, Gloves
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Infection and immunity, 81(3), 945-955 (2013-01-16)
In response to environmental fluctuations or stresses, bacteria can activate transcriptional and phenotypic programs to coordinate an adaptive response. The intracellular pathogen Legionella pneumophila converts from a noninfectious replicative form to an infectious transmissive form when the bacterium encounters alterations
Arteriosclerosis, thrombosis, and vascular biology, 33(7), 1714-1721 (2013-05-04)
HIV patients on antiretroviral therapy (HIV/ART) exhibit a unique atherogenic dyslipidemic profile with hypertriglyceridemia (HTG) and low plasma concentrations of high-density lipoprotein (HDL) cholesterol. In the Heart Positive Study of HIV/ART patients, a hypolipidemic therapy of fenofibrate, niacin, diet, and
Cardiology, 124(2), 116-125 (2013-02-23)
Although the inverse relationship between plasma levels of high-density lipoprotein (HDL) and cardiovascular disease has been largely demonstrated, many observations have suggested that the assessment of HDL functionality might be more informative than a simple measurement of HDL-cholesterol plasma levels.
Food chemistry, 138(2-3), 1109-1115 (2013-02-16)
An isotope dilution LC/mass spectrometric (ID-LC/MS) method was developed as a candidate reference method for the accurate determination of niacin in infant formula, breakfast cereals and multivitamin. After spiking nicotinamide-d(4) as an internal standard, infant formula and breakfast cereal samples
Current atherosclerosis reports, 15(5), 325-325 (2013-03-26)
GPR109A has generated expanding interest since its discovery as the receptor for niacin a decade ago, along with deorphanisation as the receptor for endogenous ligand 3-hydroxy-butyrate shortly after. This interest is generated especially because of the continuing exploration of niacin's
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service