Determination of Chlorogenic acid and Baicalin in Compounded Lonucerae Japonicae Flos acc. Chinese Pharmacopeia using a Discovery® HS C18 Column
Dean Duan
Merck, Application Scientist, China application lab, Shanghai, China
Section Overview
Introduction
Compounded Lonucerae Japonicae Flos is a kind of Traditional Chinese medicine (TCM). It has the effects of heat-clearing and detoxicating, cooling blood and detumescence. In this application, one Chinese pharmacopeia 2020 monograph method was validated using a Discovery® HS C18 HPLC column.
![Chemical structures of chlorogenic acid and baicalin 2-D chemical structures (bond line structure) of chlorogenic acid and baicalin used to measure analytes in compounded Lonucerae Japonicae Flos using a Discovery® HS C18](/deepweb/assets/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/small-molecule-hplc/chemical-structures-of-chlorogenic-acid-and-baicalin/chemical-structures-of-chlorogenic-acid-and-baicalin.jpg)
Figure 1. Chemical structures of chlorogenic acid and baicalin.
![HPLC profile of chlorogenic acid and baicalin standards Analysis of chlorogenic acid and baicalin standards used to determine the analytes in compounded Lonucerae Japonicae Flos using a Discovery® HS C18 HPLC column](/deepweb/assets/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/small-molecule-hplc/chromatogram-of-chlorogenic-acid-and-baicalin-standard-solution/chromatogram-of-chlorogenic-acid-and-baicalin-standard-solution.jpg)
Figure 2. Chromatogram of chlorogenic acid and baicalin standard solution.
![HPLC profile of compounded Lonucerae Japonicae Flos Analysis of compounded Lonucerae Japonicae Flos using Discovery® HS C18 HPLC column](/deepweb/assets/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/small-molecule-hplc/chromatogram-of-compounded-lonucerae-japonicae-flos/chromatogram-of-compounded-lonucerae-japonicae-flos.jpg)
Figure 3. Chromatogram of compounded Lonucerae Japonicae Flos.
![HPLC of solvent blank Separation of solvent blank on Discovery® HS C18 HPLC column](/deepweb/assets/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/small-molecule-hplc/chlorogenic-acid-and-baicalin-/hplc-of-solvent-blank/hplc-of-solvent-blank.jpg)
Figure 4. Chromatogram of solvent blank.
Chromatograms at 326 nm for baicalin
![HPLC profile of chlorogenic acid and baicalin standard solution Chromatographic separation of chlorogenic acid and baicalin standards in compounded Lonucerae Japonicae Flos using Discovery® HS C18 HPLC column](/deepweb/assets/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/small-molecule-hplc/chlorogenic-acid-and-baicalin-/hplc-profile-of-chlorogenic-acid-and-baicalin-standard-solution/hplc-profile-of-chlorogenic-acid-and-baicalin-standard-solution.jpg)
Figure 5. Chromatogram of chlorogenic acid and baicalin standard solution.
![HPLC profile of compounded Lonucerae Japonicae Flos Chromatogram of compounded Lonucerae Japonicae Flos to analyze chlorogenic acid and baicalin analytes using Discovery® HS C18 HPLC column](/deepweb/assets/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/small-molecule-hplc/chlorogenic-acid-and-baicalin-/hplc-profile-of-compounded-lonucerae-japonicae-flos/hplc-profile-of-compounded-lonucerae-japonicae-flos.jpg)
Figure 6. Chromatogram of compounded Lonucerae Japonicae Flos.
![HPLC of solvent blank Separation of solvent blank on Discovery® HS C18 HPLC column](/deepweb/assets/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/small-molecule-hplc/chlorogenic-acid-and-baicalin-/hplc-of-solvent-blank/hplc-of-solvent-blank.jpg)
Figure 7. Chromatogram of solvent blank.
Specificity and repeatability – chlorogenic acid and baicalin
Calibration
Calibration data – chlorogenic acid
![Calibration curve of chlorogenic acid Calibration curve of chlorogenic acid used to determine the analyte in compounded Lonucerae Japonicae Flos with Discovery® HS C18 HPLC column](/deepweb/assets/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/small-molecule-hplc/chlorogenic-acid-and-baicalin-/calibration-graph-of-chlorogenic-acid/calibration-graph-of-chlorogenic-acid.jpg)
Figure 8. Calibration curve of chlorogenic acid.
Calibration data – baicalin
![Calibration graph of baicalin Calibration curve of baicalin used to determine the analyte in compounded Lonucerae Japonicae Flos with Discovery® HS C18 HPLC column](/deepweb/assets/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/small-molecule-hplc/chlorogenic-acid-and-baicalin-/calibration-graph-of-baicalin/calibration-graph-of-baicalin.jpg)
Figure 9. Calibration curve of baicalin
Conclusion
The Chinese pharmacopeia 2020 monograph method was reproduced using a Discovery® HS C18 HPLC column. For the shown method, the limit of detection (LOD) and the limit of quantitation (LOQ) were found to be 0.07 µg/mL and 0.21 µg/mL, respectively, for chlorogenicacid, while the limit of detection (LOD) and the limit of quantitation (LOQ) were 0.27 µg/mL and 0.82 µg/mL, respectively, for baicalin. The method can be used for determination of chlorogenicacid and baicalin in compounded Lonucerae Japonicae Flos according to the Chinese pharmacopoeia 2020.
To continue reading please sign in or create an account.
Don't Have An Account?