콘텐츠로 건너뛰기
Merck
  • Optimization of an analytical methodology for the simultaneous determination of different classes of ultraviolet filters in cosmetics by pressurized liquid extraction-gas chromatography tandem mass spectrometry.

Optimization of an analytical methodology for the simultaneous determination of different classes of ultraviolet filters in cosmetics by pressurized liquid extraction-gas chromatography tandem mass spectrometry.

Journal of chromatography. A (2015-06-21)
Marlene Vila, J Pablo Lamas, Carmen Garcia-Jares, Thierry Dagnac, Maria Llompart
초록

A methodology based on pressurized liquid extraction (PLE) followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) has been developed for the simultaneous analysis of different classes of UV filters including methoxycinnamates, benzophenones, salicylates, p-aminobenzoic acid derivatives, and others in cosmetic products. The extractions were carried out in 1mL extraction cells and the amount of sample extracted was only 100mg. The experimental conditions, including the acetylation of the PLE extracts to improve GC performance, were optimized by means of experimental design tools. The two main factors affecting the PLE procedure such as solvent type and extraction temperature were assessed. The use of a matrix matched approach consisting of the addition of 10μL of diluted commercial cosmetic oil avoided matrix effects. Good linearity (R(2)>0.9970), quantitative recoveries (>80% for most of compounds, excluding three banned benzophenones) and satisfactory precision (RSD<10% in most cases) were achieved under the optimal conditions. The validated methodology was successfully applied to the analysis of different types of cosmetic formulations including sunscreens, hair products, nail polish, and lipsticks, amongst others.

MATERIALS
제품 번호
브랜드
제품 설명

Sigma-Aldrich
Methanol, NMR reference standard
Sigma-Aldrich
(±)-Camphor, meets analytical specification of Ph. Eur., BP, racemic, ≥95% (GC)
Sigma-Aldrich
(±)-Camphor, ≥95.5%
Sigma-Aldrich
2-Ethylhexyl 2-cyano-3,3-diphenylacrylate, 97%
Sigma-Aldrich
Acetone, natural, ≥97%
Sigma-Aldrich
Acetone, ≥99%, meets FCC analytical specifications
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Camphor, 96%
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Ethyl acetate, ReagentPlus®, ≥99.8%
Sigma-Aldrich
Pyridine, ≥99%
Millipore
Ethyl acetate, suitable for HPLC, ≥99.8% (GC)
Sigma-Aldrich
Ethyl acetate, natural, ≥99%, FCC, FG
Sigma-Aldrich
Hexane, anhydrous, 95%
Sigma-Aldrich
Ethyl acetate, ≥99%, FCC, FG
Sigma-Aldrich
Ethyl acetate, anhydrous, 99.8%
Sigma-Aldrich
Pyridine, anhydrous, 99.8%
Sigma-Aldrich
Benzophenone, purified by sublimation, ≥99%
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acetic anhydride, ReagentPlus®, ≥99%
Sigma-Aldrich
Acetic anhydride, 99.5%
Sigma-Aldrich
Benzophenone, ReagentPlus®, 99%
Sigma-Aldrich
Acetic anhydride, ACS reagent, ≥98.0%
Sigma-Aldrich
Ultrapure Acetonitrile