콘텐츠로 건너뛰기
Merck

Fluorometric quantitation of cellular and nonprotein thiols.

Analytical biochemistry (1986-04-01)
F C Ayers, G L Warner, K L Smith, D A Lawrence
초록

A microfluorometric assay for thiols has been developed using the thiol-specific fluorochrome N-[4-(7-diethylamino-4-methyl-3-coumarinyl)phenyl]maleimide (CPM). The technique may be used to quantitate either cellular or plasma thiols over a range of 0.01 to 3.0 nmol and may be used with as few as 1-3 X 10(5) cells giving highly proportional and reproducible results. Values for nonprotein thiols obtained with this assay agree well with previous reports on glutathione (GSH) levels for both lymphocytes and plasma. Readings are determined with the aid of an automated fluorescence microplate reader which allows up to 96 samples, including standards, to be read at the same time. Cellular thiols accessible after lysis were also quantitated before and after treatment of intact cells with various thiol-reactive chemicals. Interestingly, HgCl2, bromoethanesulfonic acid, and N-ethylmaleimide differentially modified protein and nonprotein thiol levels.

MATERIALS
제품 번호
브랜드
제품 설명

Sigma-Aldrich
7-Diethylamino-3-(4-maleimidophenyl)-4-methylcoumarin, suitable for fluorescence, BioReagent, ≥90% (HPCE)
Sigma-Aldrich
7-Diethylamino-3-(4-maleimidophenyl)-4-methylcoumarin, ≥95% (HPLC), solid