추천 제품
종 반응성
rat
포장
kit of 96 wells (12 strips x 8 wells)
기술
ELISA: suitable
capture ELISA: suitable
입력
sample type plasma
sample type serum
sample type cell culture supernatant(s)
assay range
inter-assay cv: <12%
intra-assay cv: <10%
sensitivity: 20 pg/mL
standard curve range: 28.81-7000 pg/mL
검출 방법
colorimetric
배송 상태
wet ice
저장 온도
−20°C
유전자 정보
rat ... Icam1(15894)
일반 설명
The Rat ICAM-1 (Intercellular Adhesion Molecule-1) ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme- linked immunosorbent assay for the quantitative measurement of Rat ICAM- 1 in serum, plasma, cell culture supernatants and urine.
면역원
Recombinant Rat ICAM1
애플리케이션
For research use only. Not for use in diagnostic procedures.
Please refer to the attached General ELISA KIT Procedure (sandwich, competitive & Indirect ELISA)
Please refer to the attached General ELISA KIT Procedure (sandwich, competitive & Indirect ELISA)
기타 정보
A sample Certificate of Analysis is available for this product.
Please type the word sample in the text box provided for lot number.
Please type the word sample in the text box provided for lot number.
신호어
Warning
유해 및 위험 성명서
예방조치 성명서
Hazard Classifications
Met. Corr. 1
Storage Class Code
8A - Combustible corrosive hazardous materials
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
International journal of cardiology, 176(1), 139-144 (2014-08-03)
Coagulation and prothrombotic potential have genuinely been associated with increased cardiovascular risk. However, not all studies in this regard are conclusive. Some clinical trials have shown an increased frequency of cardiovascular complications in patients receiving direct thrombin inhibitors. Previous data
Anadolu kardiyoloji dergisi : AKD = the Anatolian journal of cardiology, 14(3), 274-279 (2014-06-18)
To investigate preoperative and postoperative blood levels of soluble intercellular and vascular cell adhesion molecules (sICAM-1, sVCAM-1) in patients with and without pulmonary hypertension (PAH) due to congenital heart disease and left to right (L-R) shunt and to determine whether
Radiation research, 181(5), 521-530 (2014-04-12)
In the event of a nuclear incident in a heavily populated area, the surge in demand for medical evaluation will likely overwhelm our emergency care system, compromising our ability to care for victims with life-threatening injuries or exposures. Therefore, there
Metabolism: clinical and experimental, 63(6), 860-873 (2014-04-02)
To determine the effect of maternal obesity and gestational diabetes mellitus (GDM) on the expression and release of genes involved in endothelial cell dysfunction in human placenta and omental adipose tissue. Human placenta and omental adipose tissue were obtained from
Biomarkers : biochemical indicators of exposure, response, and susceptibility to chemicals, 19(5), 356-367 (2014-05-24)
Biomarkers of biological effect (BOBE) have been proposed as potential tools to assess tobacco product use, toxicity and disease risk. To determine if candidate BOBE can distinguish between smokers, never-smokers and former smokers. Biomarker levels were compared from 143 smokers
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.