grade
purum
분석
≥95%
형태
solid
density
2.03 g/mL at 25 °C (lit.)
음이온 미량물
chloride (Cl-): ≤500 mg/kg
양이온 미량물
Fe: ≤50 mg/kg
Ni: ≤1000 mg/kg
Pb: ≤50 mg/kg
Zn: ≤200 mg/kg
SMILES string
O.[Co++].[O-]S([O-])(=O)=O
InChI
1S/Co.H2O4S.H2O/c;1-5(2,3)4;/h;(H2,1,2,3,4);1H2/q+2;;/p-2
InChI key
BGORGFZEVHFAQU-UHFFFAOYSA-L
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Cobalt(II) sulfate heptahydrate is a hydrated cobalt salt. Its bioavailability has been assessed in human tissue fluids and human serum.
애플리케이션
Cobalt(II) sulfate heptahydrate may be used in the following processes:
- Preparation of FeCo alloy magnetic nanofluids.
- As a source of cobalt ion (Co2+) for the oxidation of aqueous phenol solution via electro-Fenton process.
- Preparation of palladium-activated titanium dioxide-supported cobalt-nickel-phosphorus ternary alloy catalyst (Co-Ni-P/Pd-TiO2).
- Preparation of {[Co(phen)2]2(μ-P2O7)}·6MeOH (P2O7 = pyrophosphate; phen = 1,10-phenanthroline), a pyrophosphatobridged cobalt(II) coordination complex.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Carc. 1B Inhalation - Eye Irrit. 2 - Muta. 2 - Repr. 1B - Resp. Sens. 1 - Skin Sens. 1
Storage Class Code
6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
Nanoscale research letters, 8(1), 540-540 (2013-12-24)
In this research, FeCo alloy magnetic nanofluids were prepared by reducing iron(III) chloride hexahydrate and cobalt(II) sulfate heptahydrate with sodium borohydride in a water/CTAB/hexanol reverse micelle system for application in magnetic hyperthermia treatment. X-ray diffraction, electron microscopy, selected area electron
Synthesis, Structural, Thermal and Magnetic Characterization of a Pyrophosphato-Bridged Cobalt (II) Complex.
European Journal of Inorganic Chemistry, 2008(17), 2691-2697 (2008)
Journal of environmental monitoring : JEM, 5(4), 675-680 (2003-09-02)
Testing of metal compounds for solubility in artificial fluids has been used for many years to assist determining human health risk from exposure to specific compounds of concern. In lieu of obtaining bioavailability data from samples of urine, blood, or
Phenol degradation by advanced electrochemical oxidation process electro-Fenton using a carbon felt cathode.
Applied Catalysis. B, Environmental, 83(1), 140-149 (2008)
Hydrogen generation from the hydrolysis of ammonia borane using cobalt-nickel-phosphorus (Co-Ni-P) catalyst supported on Pd-activated TiO2 by electroless deposition.
International Journal of Hydrogen Energy, 36(11), 254-261 (2011)
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.