추천 제품
Grade
analytical standard
유통기한
limited shelf life, expiry date on the label
농도
50 μg/mL in isooctane
기술
HPLC: suitable
gas chromatography (GC): suitable
응용 분야
environmental
형식
single component solution
저장 온도
2-8°C
SMILES string
Brc1ccc(Oc2ccc(Br)c(Br)c2)c(Br)c1
InChI
1S/C12H6Br4O/c13-7-1-4-12(11(16)5-7)17-8-2-3-9(14)10(15)6-8/h1-6H
InChI key
DHUMTYRHKMCVAG-UHFFFAOYSA-N
일반 설명
BDE No 66 is an environmental pollutant with low acute toxicity, belonging to the group of polybrominated diphenyl ethers. It finds a large number of applications as additive flame-retardants in consumer products ranging from textiles to polymers.
애플리케이션
BDE No 66 may be used as an analytical reference standard to quantify the analyte in environmental samples using gas chromatography coupled to mass spectrometry (GC-MS) and selective pressurized liquid extraction followed by gas chromatography coupled to negative ion chemical ionization-mass spectrometry (GC-NCI-MS).
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
기타 정보
The customer needs to make sure that the standard is homogeneous, this can be achieved by shaking, vortexing , or sonicating the ampoule before opening the ampoule. Care should be taken when opening the ampoule to avoid any injuries from the broken glass.
The standard should be transferred to a clean and appropriate vial or flask using clean pipettes or micro pipettes. The vial should be immediately capped to avoid any loss or evaporation of the solvent.
After opening the ampoule, the standard should not be stored or kept in the ampoule. To preserve the integrity of the product, the standard should be transferred to an appropriate vial that must be capped and stored according to the recommendation on the Certificate of Analysis.
The standard should be transferred to a clean and appropriate vial or flask using clean pipettes or micro pipettes. The vial should be immediately capped to avoid any loss or evaporation of the solvent.
After opening the ampoule, the standard should not be stored or kept in the ampoule. To preserve the integrity of the product, the standard should be transferred to an appropriate vial that must be capped and stored according to the recommendation on the Certificate of Analysis.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3
표적 기관
Central nervous system
Storage Class Code
3 - Flammable liquids
WGK
WGK 2
Flash Point (°F)
10.4 °F - closed cup
Flash Point (°C)
-12 °C - closed cup
개인 보호 장비
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
Determination of potential sources of PCBs and PBDEs in sediments of the Niagara River.
Environmental Pollution (Barking, Essex : 1987), 139(2), 489-497 (2006)
Determination of decabromodiphenyl ether in sediments using selective pressurized liquid extraction followed by GC-NCI-MS.
Analytical and Bioanalytical Chemistry, 378(3), 610-614 (2004)