Visit our Sensor Applications portal to learn more.
애플리케이션
Carbonate ionophore IV solution (4-Butyl-a,a,a-trifluoroacetophenone) was used in optimization of liquid membrane-cellophane electrodes to develop a carbonate-selective electrode for direct measurement of CO2 at physiological pH.
포장
Bottomless glass bottle. Contents are inside inserted fused cone.
물리적 형태
solution in 0.5 mL tetrahydrofuran
기타 정보
Lipophilic, neutral ionophore for the determination of carbonate and hydroxide with solvent polymeric membrane electrodes
법적 정보
Selectophore is a trademark of Merck KGaA, Darmstadt, Germany
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Oral - Carc. 2 - Eye Irrit. 2 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3
표적 기관
Central nervous system, Respiratory system
보충제 위험성
Storage Class Code
3 - Flammable liquids
WGK
WGK 3
Flash Point (°F)
1.4 °F - closed cup
Flash Point (°C)
-17 °C - closed cup
개인 보호 장비
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
Biosensors & bioelectronics, 18(2-3), 245-253 (2002-12-18)
A carbonate ion-selective electrode for determination of total carbon dioxide species such as carbon dioxide, bicarbonate and carbonate with reduced interference from salicylate is described. Derivatives of trifluoroacetophenone were used as neutral carriers for carbonate. A polymer-free liquid carbonate-selective membrane
Role of trifluoroacetophenone solvents and quaternary ammonium salts in carbonate-selective liquid membrane electrodes
Analytical Chemistry, 59 (1), 144-150 (1987)
Analytical chemistry, 63(6), 596-603 (1991-03-15)
On the basis of previously reported correlations between the lipophilicity of membrane components, their partition coefficient between the membrane and the sample, and the lifetime of corresponding neutral-carrier-based sensors, the lipophilicities of ionophores and plasticizers in analytically relevant ion-selective electrodes
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..