추천 제품
분석
97%
refractive index
n20/D 1.386 (lit.)
bp
114 °C (lit.)
density
1.419 g/mL at 25 °C (lit.)
SMILES string
FC(F)(F)CC[Si](Cl)(Cl)Cl
InChI
1S/C3H4Cl3F3Si/c4-10(5,6)2-1-3(7,8)9/h1-2H2
InChI key
WEUBQNJHVBMUMD-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
Trichloro(3,3,3-trifluoropropyl)silane can be used as a precursor for the preparation of:
It can also be used as a silanizing agent to coat the inner surface of pipettes in order to investigate the electrical charging of droplets discharged from the micropipette.
- Fluorinated polyhedral oligomeric silsesquioxane (F-POSS) by base-catalyzed condensation.
- 3,3,3-Trifluoropropyltrimethoxysilane by alcoholysis reaction with methanol.
It can also be used as a silanizing agent to coat the inner surface of pipettes in order to investigate the electrical charging of droplets discharged from the micropipette.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Flam. Liq. 3 - Skin Corr. 1B
보충제 위험성
Storage Class Code
3 - Flammable liquids
WGK
WGK 3
Flash Point (°F)
113.7 °F - closed cup - (own results)
Flash Point (°C)
45.4 °C - closed cup - (own results)
개인 보호 장비
Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
Scientific reports, 3, 2037-2037 (2013-06-21)
We report that a droplet dispensed from a micropipette almost always has a considerable electrical charge of a magnitude dependent on the constituents of the droplet, on atmospheric humidity and on the coating material of pipette tip. We show that
Chemical communications (Cambridge, England), (47), 4992-4994 (2007-12-01)
New fluorinated polyhedral oligomeric silsesquioxane (F-POSS) structures possessing a high degree of hydrophobicity have been prepared via a facile corner-capping methodology.
Fabrication of Carbon Nanotube High-Frequency Nanoelectronic Biosensor for Sensing in High Ionic Strength Solutions
Journal of Visualized Experiments, 77, e50438-e50438 (2013)
Langmuir, 11, 136-136 (1995)
Electrophoresis, 24(18), 3253-3259 (2003-10-01)
Capillary electrochromatography (CEC) and preconcentration of neutral compounds have been realized on poly(dimethylsiloxane) (PDMS) microchips. The channels are coated with polyelectrolyte multilayers to avoid absorption of hydrophobic analytes into PDMS. The structures of a microchip include an injector and a
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..