Skip to Content
Merck
  • Mass spectrometric behavior of phenolic acids standards and their analysis in the plant samples with LC/ESI/MS system.

Mass spectrometric behavior of phenolic acids standards and their analysis in the plant samples with LC/ESI/MS system.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-07-27)
Wojciech Ostrowski, Anna Wojakowska, Magdalena Grajzer, Maciej Stobiecki
ABSTRACT

Liquid chromatography coupled to mass spectrometry (MS) with electrospray ionization (ESI) is one of analytical techniques to obtain accurate results of low molecular weight aromatic compounds in biological samples of different origin. The interpretations of mass spectra of these aromatic compounds in the negative spectra registered in the full scan MS mode may be uneasy due to presence of deprotonated molecules [M-H](-) from different co-eluting entities, fragment ions created after the break-up of precursor ions and also ions representing modified molecules clusters. Thus, the first aim of this study was to evaluate general parameters during analysis performed in the full scan MS or MS/MS mode. Secondly, to set general fragmentation rules for aromatic compounds and entities in a complex biological matrix. We established that different groups of low molecular weight phenolic acids form unique adduct ions and additionally registration LC/MS/MS spectra with two different collision energies may allow for differentiating isomeric or isobaric molecules. These findings together with some general fragmentation rules can facilitate identifications of aromatic acids as we outlined in the sample of cold-pressed rose-hip oil and lupine leaves extract.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetonitrile solution, contains 10.0% acetone, 0.05% formic acid, 40.0% 2-propanol
Sigma-Aldrich
Methanol, suitable for HPLC
Sigma-Aldrich
Methanol, JIS special grade, ≥99.8%
Supelco
Salicylic acid, 1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (w/v) ammonium formate, 5 % (v/v) water, 0.1 % (v/v) formic acid, suitable for HPLC
Supelco
Melting point standard 182-184°C, analytical standard
Supelco
Salicylic acid, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, NMR reference standard
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (v/v) trifluoroacetic acid
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%, poly-coated bottles
Supelco
Mettler-Toledo Calibration substance ME 51143093, Vanillin, traceable to primary standards (LGC)
Sigma-Aldrich
Methanol, SAJ first grade, ≥99.5%
Sigma-Aldrich
Methanol, JIS 300, ≥99.8%, for residue analysis
Sigma-Aldrich
2-Hydroxyphenylacetic acid, ReagentPlus®, 99%
Sigma-Aldrich
3-Hydroxyphenylacetic acid, ≥99%
Sigma-Aldrich
Sinapic acid, ≥98%, powder
Sigma-Aldrich
Homovanillic acid, Fluorimetric reagent
Sigma-Aldrich
Salicylic acid, BioXtra, ≥99.0%
Sigma-Aldrich
p-Coumaric acid, ≥98.0% (HPLC)
Sigma-Aldrich
Salicylic acid, suitable for plant cell culture
Supelco
Methanol, analytical standard
Supelco
Sinapic acid, matrix substance for MALDI-MS, ≥99.0% (T)
Sigma-Aldrich
Acetovanillone, ≥98%, FG
Sigma-Aldrich
4-Hydroxybenzaldehyde, ≥95.0% (HPLC)
Supelco
Mettler-Toledo Calibration substance ME 18555, Benzoic acid, analytical standard, (for the calibration of the melting point system), traceable to primary standards (LGC)
Sigma-Aldrich
Salicylic acid, meets analytical specification of Ph. Eur., BP, USP, 99.5-100.5% (calc. to the dried substance)
Sigma-Aldrich
p-Anisic acid, ≥99%, FG
Sigma-Aldrich
Methanol, anhydrous, 99.8%