コンテンツへスキップ
Merck
  • Determination of the maleic acid in rat urine and serum samples by isotope dilution-liquid chromatography-tandem mass spectrometry with on-line solid phase extraction.

Determination of the maleic acid in rat urine and serum samples by isotope dilution-liquid chromatography-tandem mass spectrometry with on-line solid phase extraction.

Talanta (2015-02-24)
Hsin-Chang Chen, Charlene Wu, Kuen-Yuh Wu
要旨

A rapid and simple on-line solid-phase extraction coupled with isotope dilution-liquid chromatography-tandem mass spectrometry (SPE-ID-LC-MS/MS) method was developed to quantitate maleic acid in serum and urine of SpragueDawley (SD) rats. The aforementioned biological samples were spiked with (13)C2-maleic acid, vigorously vortexed, added with acetonitrile to precipitate proteins, and then injected into the on-line SPE-LC-MS/MS system for quantification. Upon validation, this method demonstrated excellent feasibility and sensitivity: calibration curves for maleic acid in serum and urine display excellent linearity with the coefficient of determination (R(2)) greater than 0.999; the limits of detection and quantitation (LOD and LOQ) for maleic acid were determined at 0.2 and 0.5μg L(-1), respectively. Additionally, intra-day accuracy for maleic acid in serum and urine samples ranged from 94.0% to 100.2% and 101.3% to 104.4%, respectively. Furthermore, inter-day accuracy ranged from 93.6% to 101.0% and from 102.3% to 111.4% in serum and urine samples, respectively. Intra-day precision %RSD of maleic acid in serum and urine samples was 13.8% or less, whereas the inter-day precision was 6.1% or less. The matrix effects were not found to be statistically significant (p=0.9145 and p=0.5378, correspondingly) based on the calculations of recovery functions. The collected serum and urine samples were analyzed using SPE-ID-LC-MS/MS. Our results reveal trace levels of maleic acid in the control rats, demonstrating that this method is capable of analyzing background levels of contaminants in biofluids with excellent sensitivity and specificity at part-per-billion levels concentrations in complex matrices.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
酢酸アンモニウム, ACS reagent, ≥97%
Sigma-Aldrich
アセトニトリル, ACS reagent, ≥99.5%
Sigma-Aldrich
アセトニトリル, for HPLC, for UV, ≥99.9% (GC)
Sigma-Aldrich
酢酸アンモニウム, ≥99.99% trace metals basis
Sigma-Aldrich
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
酢酸アンモニウム, for molecular biology, ≥98%
Sigma-Aldrich
アセトニトリル, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
酢酸アンモニウム 溶液, for molecular biology, 7.5 M
Sigma-Aldrich
アセトニトリル, biotech. grade, ≥99.93%
Sigma-Aldrich
酢酸アンモニウム, 99.999% trace metals basis
Sigma-Aldrich
アセトニトリル, anhydrous, 99.8%
Sigma-Aldrich
酢酸アンモニウム, JIS special grade, ≥97.0%
Sigma-Aldrich
マレイン酸, ReagentPlus®, ≥99% (HPLC)
USP
マレイン酸, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
アセトニトリル, ReagentPlus®, 99%
Sigma-Aldrich
アセトニトリル, electronic grade, 99.999% trace metals basis
Supelco
酢酸アンモニウム, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
アセトニトリル, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
アセトニトリル, ≥99.8%, suitable for HPLC
Supelco
アセトニトリル, Pharmaceutical Secondary Standard; Certified Reference Material
USP
アセトニトリル 溶液, United States Pharmacopeia (USP) Reference Standard
Supelco
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9% (GC)
Sigma-Aldrich
アセトニトリル, ≥99.8%, for residue analysis, JIS 300
Sigma-Aldrich
酢酸アンモニウム, reagent grade, ≥98%
Sigma-Aldrich
アセトニトリル, JIS special grade, ≥99.5%
Supelco
マレイン酸, Standard for quantitative NMR, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
酢酸アンモニウム, BioXtra, ≥98%
Sigma-Aldrich
酢酸アンモニウム 溶液, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
酢酸アンモニウム, BioUltra, for molecular biology, ≥99.0%