コンテンツへスキップ
Merck
  • Anodic TiO2 nanotubular arrays with pre-synthesized hydroxyapatite--an effective approach to enhance the biocompatibility of titanium.

Anodic TiO2 nanotubular arrays with pre-synthesized hydroxyapatite--an effective approach to enhance the biocompatibility of titanium.

Journal of nanoscience and nanotechnology (2013-07-26)
Lu-Ning Wang, Long-Xiang Lin, Chang-Jian Lin, Chen Shen, Alyssa Shinbine, Jing-Li Luo
要旨

Electrochemically anodized TiO2 nanotubular arrays can provide large surface areas for biological species attachment. In order to further enhance the biocompatibility of Ti medical implants, we deposited a pre-synthesized hydroxyapatite inside and on the nanotubular arrays, and examined the biocompatibility of the anodized TiO2 nanotubular arrays with pre-synthesized hydroxyapatite by in vitro assessment in simulated body fluid, and in vitro cell culture. The results showed that the hydroxyapatite coating was able to be induced on TiO2 nanotubular arrays with pre-synthesized hydroxyapatite within 5 days while only a thin film composed of calcium phosphorous chemicals formed on as-formed TiO2 nanotubular arrays. The cell culture evaluation further proved the enhancement of cell attachment and proliferation on TiO2 nanotubular arrays with pre-synthesized hydroxyapatite as opposed to those without pre-synthesized hydroxyapatite. The present study proves that formation of TiO2 nanotubular arrays with pre-synthesized hydroxyapatite a promising method to enhance the biocompatibility of Ti implants.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
酸化チタン(IV), nanopowder, 21 nm primary particle size (TEM), ≥99.5% trace metals basis
Sigma-Aldrich
酸化チタン(IV)、アナターゼ, nanopowder, <25 nm particle size, 99.7% trace metals basis
Sigma-Aldrich
酸化チタン(IV), puriss., meets analytical specification of Ph. Eur., BP, USP, 99-100.5%
Sigma-Aldrich
酸化チタン(IV)、アナターゼ, powder, 99.8% trace metals basis
Sigma-Aldrich
酸化チタン(IV), ReagentPlus®, ≥99%
Sigma-Aldrich
酸化チタン(IV)、ルチル, powder, <5 μm, ≥99.9% trace metals basis
Sigma-Aldrich
酸化チタン(IV)、アナターゼ, powder, −325 mesh, ≥99% trace metals basis
Sigma-Aldrich
酸化チタン(IV)、ルチル, nanopowder, <100 nm particle size, 99.5% trace metals basis
Sigma-Aldrich
酸化チタン(IV)、ルチル型/アナターゼ型混合物, nanopowder, <100 nm particle size (BET), 99.5% trace metals basis
Sigma-Aldrich
チタン, powder, <45 μm avg. part. size, 99.98% trace metals basis
Sigma-Aldrich
チタン, foil, thickness 0.127 mm, 99.7% trace metals basis
Sigma-Aldrich
チタン, foil, thickness 0.25 mm, 99.7% trace metals basis
Sigma-Aldrich
酸化チタン(IV)、ルチル型/アナターゼ型混合物, nanoparticles, <150 nm particle size (volume distribution, DLS), dispersion, 40 wt. % in H2O, 99.5% trace metals basis
Sigma-Aldrich
チタン, powder, −100 mesh, 99.7% trace metals basis
Sigma-Aldrich
酸化チタン(IV)、ルチル, ≥99.98% trace metals basis
Sigma-Aldrich
酸化チタン(IV)、ルチル, 99.995% trace metals basis
Sigma-Aldrich
酸化チタン(IV), contains 1% Mn as dopant, nanopowder, <100 nm particle size (BET), ≥97%
Sigma-Aldrich
チタン, wire, diam. 0.25 mm, 99.7% trace metals basis
Sigma-Aldrich
チタン, sponge, 1-20 mm, 99.5% trace metals basis
Sigma-Aldrich
チタン, foil, thickness 2.0 mm, 99.7% trace metals basis
Sigma-Aldrich
チタン, foil, thickness 0.025 mm, 99.98% trace metals basis
Sigma-Aldrich
ヒドロキシアパタイト, puriss., meets analytical specification of Ph. Eur., BP, FCC, E341, ≥90% (calculated on glowed substance)
Sigma-Aldrich
チタン, foil, thickness 0.5 mm, 99.99% trace metals basis
Sigma-Aldrich
チタン, sputtering target, diam. × thickness 2.00 in. × 0.25 in., 99.995% trace metals basis
Sigma-Aldrich
チタン, wire, diam. 1.0 mm, 99.99% trace metals basis
Sigma-Aldrich
チタン, 5-10 mm, ≥99.99% trace metals basis (purity exclusive of Na and K content)
Sigma-Aldrich
ヒドロキシアパタイト, purum p.a., ≥90% (as Ca3(PO4)2, KT)
Sigma-Aldrich
チタン, foil, thickness 0.127 mm, ≥99.99% trace metals basis
Sigma-Aldrich
チタン, foil, thickness 0.25 mm, 99.99% trace metals basis
Sigma-Aldrich
酸化チタン(IV)、ルチル, <001>, (single crystal substrate), ≥99.9% trace metals basis, L × W × thickness 10 mm × 10 mm × 0.5 mm