グレード
analytical standard
包装
ampule of 1000 mg
テクニック
HPLC: suitable
gas chromatography (GC): suitable
mp
187-189 °C (lit.)
密度
1.374 g/mL at 25 °C (lit.)
アプリケーション
environmental
SMILES記法
Nc1ccc(cc1)C(O)=O
InChI
1S/C7H7NO2/c8-6-3-1-5(2-4-6)7(9)10/h1-4H,8H2,(H,9,10)
InChI Key
ALYNCZNDIQEVRV-UHFFFAOYSA-N
類似した製品をお探しですか? 訪問 製品比較ガイド
危険有害性情報
注意書き
危険有害性の分類
Aquatic Chronic 3
保管分類コード
11 - Combustible Solids
WGK
WGK 2
引火点(°F)
339.8 °F - closed cup
引火点(℃)
171 °C - closed cup
個人用保護具 (PPE)
dust mask type N95 (US), Eyeshields, Faceshields, Gloves
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Jan Code
442401:
Journal of natural products, 76(1), 91-96 (2013-01-16)
During a survey of actinobacteria known to suppress the growth of Streptomyces scabies (the causative agent of potato scab disease) in vivo, six new rhamnosylated alkaloids, the solphenazines A-F (1-6), were isolated from a biological control strain of Streptomyces (DL-93).
Water research, 47(1), 153-162 (2012-10-23)
Dissolved organic matter (DOM) is an important photosensitizer for the phototransformation of organic contaminants in sunlit natural waters. This article focuses on the photolysis kinetics and mechanism of sunscreen agent p-aminobenzoic acid (PABA) in the presence of four kinds of
Radiology, 263(2), 451-460 (2012-03-23)
To evaluate myeloperoxidase (MPO) as a newer therapeutic target and bis-5-hydroxytryptamide-diethylenetriaminepentaacetate-gadolinium (Gd) (MPO-Gd) as an imaging biomarker for demyelinating diseases such as multiple sclerosis (MS) by using experimental autoimmune encephalomyelitis (EAE), a murine model of MS. Animal experiments were approved
Magnetic resonance in chemistry : MRC, 50(6), 443-448 (2012-05-04)
Longitudinal multispin order (LOMO) corresponds to a nonequilibrium population distribution in spin systems that exhibit scalar (J), dipolar, or quadrupolar coupling. We investigated the relaxation of longitudinal two-spin order (2-LOMO) in systems that had either weakly or strongly J-coupled spins.
Biosensors & bioelectronics, 36(1), 81-88 (2012-04-28)
The preparation and performance of a disposable amperometric immunosensor, based on the use of a selective capture antibody and screen-printed carbon electrodes (SPCEs), for the specific detection and quantification of sulfonamide residues in milk is reported. The antibody was covalently
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)