おすすめの製品
ligand
recombinant protein G fragment and recombinant protein binding HSA
特徴
wetted part: no
包装
pack of 2 × 1 mL
メーカー/製品名
Cytiva 28-9466-03
保管条件
(20% Ethanol)
ベッドサイズ
7 mm × 25 mm
ベッド容積
1 mL
カラム内径
7 mm
平均部品サイズ
34 μm
cleaning
2-9
動作範囲
3-9
保管温度
2-8°C
詳細
HiTrap® Albumin & IgG Depletion is prepacked columns for the depletion of albumin and IgG from human serum and plasma. The columns are prepacked with high performance SepharoseTM based media with an affinity for human serum albumin (HSA) and IgG.
アプリケーション
HiTrap® Albumin & IgG Depletion and Albumin & IgG Depletion SpinTrap™ are prepacked columns for the depletion of albumin and IgG from plasma and serum samples. Albumin and IgG are the most abundant plasma Proteins, and they tend to obscure the signals of less abundant Proteins. Depletion of the two Proteins removes more than 60% of the total Protein content in human plasma, allowing a higher load of less abundant Proteins to be included in the analysis and detection of more Proteins. These columns are members of the Trap platform and address the need for flexible, small-scale preparation of Protein samples prior to downstream analyses such as 1-D or 2-D gel electrophoresis and mass spectrometry.
特徴および利点
- HiTrap® Albumin & IgG Depletion is a prepacked column for the depletion of albumin and IgG from human serum or plasma.
- HiTrap® Albumin & IgG Depletion column provides rapid and easy processing in a convenient format for handling larger sample volumes (~150 μL) using a liquid chromatography system or manually using a syringe.
- Columns are prepacked with high performance Sepharose™ based media with an affinity for human serum albumin (HSA) and IgG.
- High depletion capacity, removes > 95% HSA and > 90% IgG, with high reproducibility.
- Simple and fast procedure.
- Removal of albumin and IgG allows a higher load of less abundant Proteins to be included in the analysis and detection of more Proteins.
保管および安定性
Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
アナリシスノート
この製品の分析証明書は、www.cytiva.com.
その他情報
The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.
法的情報
HiTrap is a registered trademark of Cytiva
Sepharose is a trademark of Cytiva
SpinTrap is a trademark of Cytiva
シグナルワード
Warning
危険有害性情報
保管分類コード
3 - Flammable liquids
最新バージョンのいずれかを選択してください:
プロトコル
This page shows how to purify or remove albumin and IgG with Albumin & IgG Depletion Sepharose High Performance from Cytiva.
This page covers detailed information on cleaning procedures and recommended flow for column cleaning.
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)