コンテンツへスキップ
Merck

CGEP75TF3

Millipore

ミリポアエクスプレス(Millipore Express)® SHF、カートリッジ

cartridge nominal length 5 in. (12.5 cm), filter diam. 2.7 in. (6.9 cm), Code 7

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
23151806

物質

polypropylene support
seal (Fluorocarbon rubber)

品質水準

法規制遵守

meets FDA 21 CFR 177-182 (all component materials)

無菌性

non-sterile

滅菌適合性

autoclavable compatible
steam-in-place compatible

製品種目

EMPROVE® Filter
Millipore Express®

特徴

hydrophilic

メーカー/製品名

Millipore Express®

パラメーター

≤16.4 mL/min air diffusion at 2.75 bar (40 psig) (in water)
0.07 bar max. inlet pressure (1 psi) at 135 °C (Reverse)
0.35 bar max. inlet pressure (5 psi) at 135 °C (Forward)
1.7 bar max. inlet pressure (25 psi) at 80 °C (Forward)
1700 mbar max. differential pressure (25 psi) at 80 °C (Forward)
2.07 bar max. inlet pressure (30 psi) at 25 °C (Reverse)
340 mbar max. differential pressure (5 psi) at 135 °C (Forward)
6900 mbar max. differential pressure (100 psi) at 25 °C (Forward)
7 bar max. inlet pressure (100 psi) at 25 °C (Forward)

テクニック

sterile filtration: suitable

L

5 in.

W

2.7 in.

カートリッジの長さ(公称)

5 in. (12.5 cm)

フィルタ直径

2.7 in. (6.9 cm)

filter filtration area

0.29 m2

フィルタサイズ

5 in.

不純物

≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

マトリックス

Millipore Express® SHF

ポアサイズ

0.2 μm pore size

泡立ち点

≥4000 mbar (58 psig), air with water

カートリッジコード

Code 7

類似した製品をお探しですか? 訪問 製品比較ガイド

関連するカテゴリー

詳細

Cartridge Type: Liquid
Device Configuration: Cartridge

包装

Double Easy-Open bag

調製ノート

Sterilization Method: 25 forward or 22 forward and 3 reverse SIP cycles of 30 min at 135 °C; 25 autoclave cycles of 60 min at 126 °C

This product was manufactured with a MILLIPORE EXPRESS® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

アナリシスノート

Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L

TOC/Conductivity: After sterilization and a controlled water flush of 5.5 L, samples exhibited <500 ppb TOC per USP 643 and <1.3 μS/cm per USP 645 at 25 °C.

Bacterial Retention: Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 107 CFU/cm2 using ASTM® F838 methodology.

その他情報

Directions for Use
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
  • Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

法的情報

ASTM is a registered trademark of American Society for Testing and Materials
Emprove is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany

適切な製品が見つかりませんか。  

製品選択ツール.をお試しください


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)