Skip to Content
Merck
  • Determination of 15 sedative residues in mutton by rapid resolution liquid chromatography-tandem mass spectrometry.

Determination of 15 sedative residues in mutton by rapid resolution liquid chromatography-tandem mass spectrometry.

Journal of the science of food and agriculture (2014-06-21)
Jinmei Wei, Yuzhu Luo, Li Zhang, Suli Fang
ABSTRACT

The use of xenobiotic compounds in animal husbandry has given rise to consumer anxieties regarding residual risk and food safety. Thus, animal tissues have become main samples for residue analysis and food safety for sedatives. In this study, a rapid resolution liquid chromatography-tandem mass spectrometry (RRLC-MS/MS) method was established for the determination of 15 sedatives residues in mutton. After enzymolysis, sedatives residues in mutton were extracted by ammonium hydroxide-acetonitrile (10:90, v/v) and determined by RRLC-MS/MS with quantification by standard curve method. The calibration curves showed good linearity within the concentrations of 0.5-50 µg kg(-1) with the correlation coefficients (r(2)) ranged from 0.9639 to 0.9984. The limits of detection (LODs) and quantification (LOQs) were 0.25-2.5 and 0.5-5 µg kg(-1), respectively. The average recoveries of spikes samples were in the ranges of 74.1-116.8% with relative standard deviations of intra- and inter-day ranged from 2.6% to 11.2% and from 2.1% to 11.4%, respectively. This method is simple, sensitive and accurate in the determination of sedative residues.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Hydrogen chloride solution, 3 M in cyclopentyl methyl ether (CPME)
Sigma-Aldrich
Methanol, SAJ special grade
Sigma-Aldrich
Methanol, suitable for HPLC
Sigma-Aldrich
Hydrochloric acid solution, 0.2 M
Sigma-Aldrich
Hydrogen chloride – ethanol solution, 3% in ethanol
Sigma-Aldrich
Hydrochloric acid solution, 0.02 M
Sigma-Aldrich
Hydrochloric acid solution, 1 M
Sigma-Aldrich
Hydrochloric acid solution, SAJ first grade, 9.5-10.0%
Sigma-Aldrich
Hydrochloric acid solution, 6 M
Sigma-Aldrich
Methanol, SAJ first grade, ≥99.5%
Sigma-Aldrich
Hydrogen chloride – ethanol solution, 0.1 M in ethanol
Sigma-Aldrich
Hydrochloric acid solution, 0.1 M
Sigma-Aldrich
Methanol, JIS 300, ≥99.8%, for residue analysis
Sigma-Aldrich
Hydrochloric acid solution, 12 M
Sigma-Aldrich
Hydrochloric acid solution, 0.5 M
Sigma-Aldrich
Hydrochloric acid solution, 0.05 M
Sigma-Aldrich
Hydrochloric acid solution, 2 M
Sigma-Aldrich
Hydrochloric acid solution, 0.01 M
Sigma-Aldrich
Hydrochloric acid, SAJ super special grade, ≥35.0%
Sigma-Aldrich
Hydrochloric acid, suitable for determination of toxic metals, ≥35.0%
Sigma-Aldrich
Methanol, JIS special grade, ≥99.8%
Sigma-Aldrich
Hydrochloric acid, SAJ first grade, 35.0-37.0%
Sigma-Aldrich
Hydrochloric acid, suitable for arsenic determination, 35.0-37.0%
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (v/v) trifluoroacetic acid
Supelco
Methanol, analytical standard
Supelco
Hydrogen chloride – 2-propanol solution, ~1.25 M HCl (T), for GC derivatization, LiChropur
Supelco
Hydrogen chloride – methanol solution, ~1.25 m HCl (T), for GC derivatization, LiChropur
Supelco
Carazolol, analytical standard
Sigma-Aldrich
Xylazine hydrochloride, ≥99.0% (HPLC)
Sigma-Aldrich
Methanol, NMR reference standard