Skip to Content
Merck
  • Developing an ultra non-fouling SU-8 and PDMS hybrid microfluidic device by poly(amidoamine) engraftment.

Developing an ultra non-fouling SU-8 and PDMS hybrid microfluidic device by poly(amidoamine) engraftment.

Colloids and surfaces. B, Biointerfaces (2015-02-18)
Yubo Qin, Poying Yeh, Xingkai Hao, Xudong Cao
ABSTRACT

A new strategy to prepare an ultra non-fouling SU-8/poly(dimethylsiloxane) (PDMS) hybrid microfluidic system is presented. We report a simple method to bond both SU-8 and PDMS surfaces to prepare the hybrid microfluidic device and then simultaneously modify both SU-8 and PDMS surfaces using poly(amidoamine) (PAMAM), a highly hydrophilic dendrimer to enhance non-fouling properties of the hybrid microfluidic channel. Water contact angle, atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS) are used to characterize and confirm surface modifications. Finally the non-fouling performance of the resulting microfluidic system is tested using both microbeads and Escherichia coli O157:H7 bacterial cells. We demonstrate that the obtained hybrid microfluidic system shows a significant microbead adsorption suppression of 99.7%, an ultra non-fouling performance that has not been reported in the literature before; in addition, 95% bacteria surface adsorption suppression is also obtained. Considering the significantly improved non-fouling performance and the ease of preparing the hybrid microfluidic system, we anticipate that this strategy will find wide applications in biosensing and detection.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Ethylenediamine solution, technical, 75-80%
Sigma-Aldrich
Toluene, anhydrous, 99.8%
Sigma-Aldrich
N-Hydroxysuccinimide, 98%
Sigma-Aldrich
N-Hydroxysuccinimide, purum, ≥97.0% (T)
Sigma-Aldrich
Ethylenediamine, ReagentPlus®, ≥99%
Sigma-Aldrich
Ethylenediamine, BioXtra
Sigma-Aldrich
Toluene, suitable for HPLC, 99.9%
Sigma-Aldrich
Ethylenediamine, meets USP testing specifications
Sigma-Aldrich
Ethylenediamine, purified by redistillation, ≥99.5%
Sigma-Aldrich
Toluene, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Toluene, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
Toluene, ACS reagent, ≥99.5%
Sigma-Aldrich
1,2-Dichloroethane, anhydrous, 99.8%
Sigma-Aldrich
Ethylenediamine, puriss. p.a., absolute, ≥99.5% (GC)
Supelco
Toluene, analytical standard
Supelco
1,2-Dichloroethane, analytical standard
Supelco
Ethylenediamine, analytical standard
Sigma-Aldrich
PAMAM dendrimer, ethylenediamine core, generation 7.0 solution, 5 wt. % in methanol
Supelco
Residual Solvent - Toluene, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Toluene, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Toluene, Laboratory Reagent, ≥99.3%
Sigma-Aldrich
Toluene, ACS reagent, ≥99.5%
Sigma-Aldrich
1,2-Dichloroethane, ACS reagent, ≥99.0%
Sigma-Aldrich
Toluene, ACS reagent, ≥99.5%
Sigma-Aldrich
Toluene, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.7% (GC)