Skip to Content
Merck
  • Evaluation of chromosome aberration and micronucleus frequencies in blood lymphocytes of workers exposed to low concentrations of benzene.

Evaluation of chromosome aberration and micronucleus frequencies in blood lymphocytes of workers exposed to low concentrations of benzene.

Mutation research. Genetic toxicology and environmental mutagenesis (2014-10-26)
Piero Lovreglio, Francesca Maffei, Mariella Carrieri, Maria N D'Errico, Ignazio Drago, Patrizia Hrelia, Giovanni B Bartolucci, Leonardo Soleo
ABSTRACT

The frequency of chromosome aberrations (CA) and micronuclei (MN) was investigated in the peripheral lymphocytes of workers occupationally exposed to low or very low concentrations of benzene. The study included 43 exposed workers (all males), namely 19 fuel-tanker drivers and 24 filling-station attendants, and 31 male subjects with no occupational exposure to the toxicant (controls). Benzene exposure was verified by means of environmental monitoring with passive personal samplers (Radiello(Ā®)), and through biological monitoring, i.e. by measurement of urinary trans,trans-muconic acid, S-phenylmercapturic acid and benzene. The frequency of CA and MN in peripheral lymphocytes was determined according to standard procedures. Exposure to benzene was found to be significantly higher for fuel-tanker drivers (median 246.6 Ī¼g/m(3)) than for filling-station attendants (median 19.9 Ī¼g/m(3)). Both groups had significantly higher exposure than controls (median 4.3 Ī¼g/m(3)). No increased frequency of CA and MN was observed in either fuel-tanker drivers or filling-station attendants compared with controls. In all subjects examined as a single group, the frequency of MN was significantly dependent on age. Only in the fuel-tanker drivers was the frequency of MN found to depend not only on age, but also on exposure to benzene. In conclusion, the frequency of MN, but not of CA, could be influenced by exposure to benzene concentrations of up to one order of magnitude lower than the threshold limit value (time-weighted average).

MATERIALS
Product Number
Brand
Product Description

radielloā„¢ BTEX/VOC Starter Kit, CS2 Desorption
radielloā„¢ Diffusive Bodies, yellow, configured for reduced sampling rates, pk of 20
Supelco
radielloā„¢ BTEX Calibration Kit (Thermal Desorption)
radielloā„¢ Filtration Kit, pk of 20
Supelco
radielloā„¢ Aldehyde Calibration Standard, 50 Ī¼g/mL each component in acetonitrile, pkg of 10 mL
radielloā„¢ Diffusive Bodies, blue, configured for sampling light sensitive compounds, pk of 20
radielloā„¢ 1,3-Butadiene Starter Kit, Thermal Desorption, pkg of 1 kit (2 RAD141 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)
Supelco
radielloā„¢ BTEX Calibration Kit (CS2 Desorption)
radielloā„¢ Clips, suspending Radiello triangular support plate, pk of 20
radielloā„¢ Diffusive Bodies, white, configured for general use, pk of 20
Supelco
radielloā„¢ Methylene Blue Calibration Standard for H2S (Hydrogen Sulfide), pkg of 100 mL
radielloā„¢ Empty Storage Tubes, glass (with stopper), volume 2.8 mL, pk of 100
radielloā„¢ Cartridge Adsorbents, for sampling BTEX and VOCs (CS2 Desorption), matrix SS net (100 mesh, 5.8 mm diam.), activated with activated charcoal (30-50 mesh), pk of 20
radielloā„¢ Barcode Labels, pk of 198
radielloā„¢ Cartridge Adsorbents, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 Ī¼m, 4.8 mm diam.), Carbograph, pk of 20
radielloā„¢ Cartridge Adsorbents, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISILĀ®, pk of 20
radielloā„¢ Cartridge Adsorbents, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
radielloā„¢ Outdoor Shelter, pk of 10
radielloā„¢ Vertical Adapter, threaded for standard use, pk of 20
radielloā„¢ Triangular Support Plate, pk of 20