Skip to Content
Merck
  • Determination of solubility parameters of ionic liquids and ionic liquid/solvent mixtures from intrinsic viscosity.

Determination of solubility parameters of ionic liquids and ionic liquid/solvent mixtures from intrinsic viscosity.

Chemphyschem : a European journal of chemical physics and physical chemistry (2014-08-26)
Piyarat Weerachanchai, Yuewen Wong, Kok Hwa Lim, Timothy Thatt Yang Tan, Jong-Min Lee
ABSTRACT

The total and partial solubility parameters (dispersion, polar and hydrogen-bonding solubility parameters) of ten ionic liquids were determined. Intrinsic viscosity approaches were used that encompassed a one-dimensional method (1D-Method), and two different three-dimensional methods (3D-Method1 and 3D-Method2). The effect of solvent type, the dimethylacetamide (DMA) fraction in the ionic liquid, and dissolution temperature on solubility parameters were also investigated. For all types of effect, both the 1D-Method and 3D-Method2 present the same trend in the total solubility parameter. The partial solubility parameters are influenced by the cation and anion of the ionic liquid. Considering the effect on partial solubility parameters of the solvent type in the ionic liquid, it was observed that in both 3D methods, the dispersion and polar parameters of a 1-ethyl-3-methylimidazolium acetate/solvent (60:40 vol %) mixture tend to increase as the total solubility parameter of the solvent increases.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
1-Ethyl-3-methylimidazolium acetate, 97%
Supelco
Diethylene glycol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, NMR reference standard
Sigma-Aldrich
1-Ethyl-3-methylimidazolium acetate, ≥95.0% (HPLC)
Sigma-Aldrich
1-Butyl-3-methylimidazolium chloride, ≥99.0% (HPLC)
USP
1-Propanol, United States Pharmacopeia (USP) Reference Standard
Supelco
N,N-Dimethylformamide, analytical standard
Supelco
1-Propanol, analytical standard
Supelco
1-Butanol, analytical standard
Supelco
2-Butanol, analytical standard
Supelco
Methanol, analytical standard
Sigma-Aldrich
Ethanolamine, puriss. p.a., ACS reagent, ≥99.0% (GC/NT)
Sigma-Aldrich
1-Butanol, anhydrous, 99.8%
Sigma-Aldrich
Ethanolamine, purified by redistillation, ≥99.5%
Sigma-Aldrich
Diethylene glycol, ReagentPlus®, 99%
Sigma-Aldrich
Ethanolamine, ACS reagent, ≥99.0%
Sigma-Aldrich
2-Butanol, anhydrous, 99.5%
Sigma-Aldrich
1-Propanol, ≥99%, FG
Sigma-Aldrich
1-Butyl-3-methylimidazolium chloride, ≥98.0% (HPLC)
Supelco
Ethanolamine, analytical standard
Sigma-Aldrich
Diethylene glycol, BioUltra, ≥99.0% (GC)
Supelco
Aucubin, analytical standard
Sigma-Aldrich
Diethylene glycol, puriss. p.a., ≥99.0% (GC), colorless
Supelco
Ethanol solution, certified reference material, 2000 μg/mL in methanol
Sigma-Aldrich
1-Propanol, natural, ≥98%, FG
Sigma-Aldrich
Isopropyl alcohol, ≥99.7%, FCC, FG
Sigma-Aldrich
Propylene carbonate, anhydrous, 99.7%
Sigma-Aldrich
1-Butanol, for molecular biology, ≥99%
Sigma-Aldrich
N,N-Dimethylformamide, for molecular biology, ≥99%
Sigma-Aldrich
Ethanolamine, ≥98%