Saltar al contenido
Merck
  • Sensitivity enhancement in direct coupling of supported liquid membrane extractions to capillary electrophoresis by means of transient isotachophoresis and large electrokinetic injections.

Sensitivity enhancement in direct coupling of supported liquid membrane extractions to capillary electrophoresis by means of transient isotachophoresis and large electrokinetic injections.

Journal of chromatography. A (2015-03-10)
Pavla Pantůčková, Pavel Kubáň, Petr Boček
RESUMEN

Enhanced sensitivity for determination of basic drugs in body fluids was achieved by in-line coupling of extraction across supported liquid membrane (SLM) to large electrokinetic injection and transient isotachophoresis-capillary zone electrophoresis (tITP-CZE) in commercial CZE instrument. Twelve cm long tITP plug of 300mM ammonium acetate was formed in the separation capillary just before the electrokinetic injection of acceptor solution containing nortriptyline, haloperidol and loperamide extracted across the SLM. The tITP plug ensured efficient stacking and preconcentration of the injected basic drugs due to the tITP action of ammonium and the drugs were then separated by CZE using 5.2M acetic acid as background electrolyte. No interferences were observed from highly-abundant body fluid species (NaCl and human serum albumin) due to the excellent clean-up properties of SLMs and analytical sensitivity increased up to 340 times compared to SLM extractions coupled in-line to CZE with standard hydrodynamic injections. The SLM-tITP-CZE method was characterized by good repeatability (RSDs of peak areas below 7.8%), linearity over two orders of magnitude (r(2) better than 0.994) and limits of detection (defined as 3×S/N) between 3 and 45μg/L. Interfacing of SLM extractions to CZE instrumentation was achieved by low-cost, disposable micro-extraction devices, which can be routinely prepared in every analytical laboratory. These devices eliminated sample carry-over, minimized the need for manual sample handling and ensured fully automated determination (including extraction, injection, preconcentration and separation) of the three basic drugs in 20μL of untreated body fluids.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Alcohol etílico puro, 200 proof, for molecular biology
Sigma-Aldrich
Alcohol etílico puro, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Ácido acético, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Ácido acético, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
Alcohol etílico puro, 200 proof, HPLC/spectrophotometric grade
Sigma-Aldrich
Alcohol etílico puro, 200 proof, meets USP testing specifications
Sigma-Aldrich
Ammonium acetate, ACS reagent, ≥97%
Sigma-Aldrich
Alcohol etílico puro, 190 proof, for molecular biology
Sigma-Aldrich
Ammonium acetate, ≥99.99% trace metals basis
Sigma-Aldrich
Cloruro de sodio, for molecular biology, DNase, RNase, and protease, none detected, ≥99% (titration)
Sigma-Aldrich
Ácido acético, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Sodium chloride solution, 5 M in H2O, BioReagent, for molecular biology, suitable for cell culture
Sigma-Aldrich
Ácido acético solution, suitable for HPLC
Sigma-Aldrich
Sodium chloride solution, 0.9% in water, BioXtra, suitable for cell culture
Sigma-Aldrich
Cloruro de sodio, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99%
Sigma-Aldrich
Ácido acético, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, FCC, 99.8-100.5%
Sigma-Aldrich
Ácido acético, glacial, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8%
Sigma-Aldrich
Etanol, ACS reagent, prima fine spirit, without additive, F15 o1
SAFC
Sodium chloride solution, 5 M
Sigma-Aldrich
Ammonium acetate, for molecular biology, ≥98%
Sigma-Aldrich
Ammonium acetate solution, for molecular biology, 7.5 M
Sigma-Aldrich
Cloruro de sodio, JIS special grade, ≥99.5%
Sigma-Aldrich
Alcohol etílico puro, 200 proof, anhydrous, ≥99.5%
Sigma-Aldrich
Sodium chloride solution, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
Cloruro de sodio, BioUltra, for molecular biology, ≥99.5% (AT)
Sigma-Aldrich
Cloruro de sodio, 99.999% trace metals basis
Sigma-Aldrich
Ácido acético, for luminescence, BioUltra, ≥99.5% (GC)
USP
Ácido acético, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Ammonium acetate, 99.999% trace metals basis
Sigma-Aldrich
Ácido acético, ≥99.5%, FCC, FG