跳转至内容
Merck

270350

Sigma-Aldrich

2,2,4-三甲基戊烷

HPLC grade, ≥99.7%

别名:

异辛烷

登录查看公司和协议定价


About This Item

线性分子式:
(CH3)2CHCH2C(CH3)3
CAS号:
分子量:
114.23
Beilstein:
1696876
EC號碼:
MDL號碼:
分類程式碼代碼:
12190000
PubChem物質ID:

等級

HPLC grade

品質等級

蒸汽密度

3.9 (vs air)

蒸汽壓力

41 mmHg ( 21 °C)

化驗

≥99.7%

形狀

liquid

自燃溫度

745 °F

純化經由

glass distillation

expl. lim.

6 %

技術

HPLC: suitable

雜質

<0.020% water

蒸發殘留物

<0.0003%

折射率

n20/D 1.391 (lit.)

bp

98-99 °C (lit.)

mp

−107 °C (lit.)

密度

0.692 g/mL at 25 °C (lit.)

&lambda ;

H2O reference

紫外吸收

λ: 210 nm Amax: 1.00
λ: 220 nm Amax: 0.20
λ: 230 nm Amax: 0.10
λ: 240 nm Amax: 0.04
λ: 250-400 nm Amax: 0.01

SMILES 字串

CC(C)CC(C)(C)C

InChI

1S/C8H18/c1-7(2)6-8(3,4)5/h7H,6H2,1-5H3

InChI 密鑰

NHTMVDHEPJAVLT-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

訊號詞

Danger

危險分類

Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3

標靶器官

Central nervous system

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 2

閃點(°F)

10.4 °F - closed cup

閃點(°C)

-12 °C - closed cup

個人防護裝備

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Luyan Xue et al.
Colloids and surfaces. B, Biointerfaces, 105, 81-86 (2013-01-29)
Choline acetate is an ionic liquid composed of a kosmotropic anion and a chaotropic cation. According to Hofmeister series, a kosmotropic anion and/or a chaotropic cation could stabilize an enzyme, thereby facilitating the retention of the catalytic activity of the
Jonas Andersson et al.
Physics in medicine and biology, 56(2), 299-314 (2010-12-17)
A method to correct for the general recombination losses for liquid ionization chambers in continuous beams has been developed. The proposed method has been derived from Greening's theory for continuous beams and is based on measuring the signal from a
Swarna Bansal et al.
Journal of hazardous materials, 190(1-3), 45-50 (2011-04-05)
Separation of secondary emulsions of dispersed droplet size less than 10 μm, by means of fibrous medium is a very complex but important process. The study investigates the influence of thin fibrous filter properties, i.e. surface energy, pore size and
Yufeng Zhang et al.
Journal of chromatography. A, 1252, 67-73 (2012-07-10)
In this study, a polyethylene Pasteur pipette-based ultrasound-assisted emulsification microextraction (USAEME) applying low-density organic solvent was successfully developed for the extraction of trace levels of organochlorine pesticides (OCPs) in water samples and followed by gas chromatography-mass spectrometry (GC-MS) analysis. In
Kyung Min Park et al.
Food chemistry, 138(2-3), 733-738 (2013-02-16)
In this study, we investigated the possibility of reversed micelles, widely used as an enzyme reactor for lipases, for the determination of lipoxygenase activity. Although it is rapid and simple, reversed micelles have some limitations, such as interference by UV-absorbing

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门