Saltar al contenido
Merck

Large endolymphatic potentials from low-frequency and infrasonic tones in the guinea pig.

The Journal of the Acoustical Society of America (2013-03-08)
Alec N Salt, Jeffery T Lichtenhan, Ruth M Gill, Jared J Hartsock
RESUMEN

Responses of the ear to low-frequency and infrasonic sounds have not been extensively studied. Understanding how the ear responds to low frequencies is increasingly important as environmental infrasounds are becoming more pervasive from sources such as wind turbines. This study shows endolymphatic potentials in the third cochlear turn from acoustic infrasound (5 Hz) are larger than from tones in the audible range (e.g., 50 and 500 Hz), in some cases with peak-to-peak amplitude greater than 20 mV. These large potentials were suppressed by higher-frequency tones and were rapidly abolished by perilymphatic injection of KCl at the cochlear apex, demonstrating their third-turn origins. Endolymphatic iso-potentials from 5 to 500 Hz were enhanced relative to perilymphatic potentials as frequency was lowered. Probe and infrasonic bias tones were used to study the origin of the enhanced potentials. Potentials were best explained as a saturating response summed with a sinusoidal voltage (Vo), that was phase delayed by an average of 60° relative to the biasing effects of the infrasound. Vo is thought to arise indirectly from hair cell activity, such as from strial potential changes caused by sustained current changes through the hair cells in each half cycle of the infrasound.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Cloruro de potasio, ACS reagent, 99.0-100.5%
Sigma-Aldrich
Cloruro de potasio, for molecular biology, ≥99.0%
Sigma-Aldrich
Cloruro de potasio, puriss., meets analytical specification of Ph. Eur., BP, USP, FCC, E508, 99-100.5% (AT), ≤0.0001% Al
Sigma-Aldrich
Cloruro de potasio, powder, BioReagent, suitable for cell culture, suitable for insect cell culture, ≥99.0%
Sigma-Aldrich
Cloruro de potasio, ReagentPlus®, ≥99.0%
Sigma-Aldrich
Cloruro de potasio solution, BioUltra, for molecular biology, ~1 M in H2O
Sigma-Aldrich
Cloruro de potasio, puriss. p.a., ≥99.5% (AT)
Sigma-Aldrich
Cloruro de potasio, BioUltra, for molecular biology, ≥99.5% (AT)
Sigma-Aldrich
Cloruro de potasio, 99.999% trace metals basis
Supelco
Potassium chloride solution, for Ag/AgCl electrodes, ~3 M KCl, saturated with silver chloride
Sigma-Aldrich
Cloruro de potasio, BioXtra, ≥99.0%
Sigma-Aldrich
Cloruro de potasio, ≥99.99% trace metals basis
Supelco
Cloruro de potasio solution, BioUltra, ~3 M in H2O
Supelco
Cloruro de potasio solution, 1 M KCl
Sigma-Aldrich
Cloruro de potasio solution, suitable for atomic absorption spectrometry, 1000 ppm K+, 1 mg/mL K+
Sigma-Aldrich
Cloruro de potasio solution, 0.075 M, sterile-filtered, BioXtra, suitable for cell culture
Supelco
Cloruro de potasio solution, conductance standard A acc. to ISO 7888, 0.1 M KCl
Sigma-Aldrich
Cloruro de potasio solution, 0.01 M
Sigma-Aldrich
Cloruro de potasio, AnhydroBeads, −10 mesh, 99.999% trace metals basis
Supelco
Cloruro de potasio solution, conductance standard B acc. to ISO 7888, 0.01 M KCl
Sigma-Aldrich
Cloruro de potasio, AnhydroBeads, −10 mesh, 99.99% trace metals basis
Sigma-Aldrich
Cloruro de potasio, tested according to Ph. Eur.
Supelco
Cloruro de potasio solution, conductance standard C acc. to ISO 7888, 0.001 M KCl