50166-U
Columna para HPLC Nucleosil® C18
5 μm particle size, L × I.D. 25 cm × 4 mm
Sinónimos:
C18 Nucleosil column
About This Item
Productos recomendados
agency
suitable for USP L1
product line
Nucleosil®
feature
endcapped
manufacturer/tradename
Nucleosil®
extent of labeling
15% Carbon loading
parameter
≤70 °C temp. range
400 bar pressure (5801 psi)
technique(s)
HPLC: suitable
L × I.D.
25 cm × 4 mm
surface area
350 m2/g
matrix
octadecyl
matrix active group
C18 (octadecyl) phase
particle size
5 μm
pore size
100 Å
separation technique
reversed phase
¿Está buscando productos similares? Visita Guía de comparación de productos
Application
- HPLC analysis of mitoxantrone in mouse plasma and tissues: application in a pharmacokinetic study.: This study demonstrates the application of HPLC using a Nucleosil® C18 column for analyzing mitoxantrone levels in mouse plasma and tissues, providing valuable data for pharmacokinetic evaluations (An et al., 2010).
- Determination of pKa values of nonsteroidal anti-inflammatory drug-oxicams by RP-HPLC and their analysis in pharmaceutical dosage forms.: This research utilizes the Nucleosil® C18 HPLC column to determine the pKa values of oxicams, aiding in the quality control of pharmaceutical formulations (Demiralay et al., 2009).
- Development of an analytical method for the determination of beta2-agonist residues in animal tissues by high-performance liquid chromatography with on-line electrogenerated [Cu(HIO6)2]5- -luminol chemiluminescence detection.: The study describes a method using a Nucleosil® C18 column to detect beta2-agonist residues, showcasing its sensitivity and application in food safety analysis (Zhang et al., 2007).
- Assay of artemether, methylparaben, and propylparaben in a formulated pediatric antimalarial dry suspension.: Utilizing the Nucleosil® C18 column, this study establishes an assay for key components in pediatric antimalarial formulations, contributing to better quality control (Atemnkeng et al., 2007).
Legal Information
Storage Class
11 - Combustible Solids
wgk_germany
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
Elija entre una de las versiones más recientes:
Certificados de análisis (COA)
Lo sentimos, en este momento no disponemos de COAs para este producto en línea.
Si necesita más asistencia, póngase en contacto con Atención al cliente
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Los clientes también vieron
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico