Skip to Content
Merck
  • Development and validation of an ultra high performance liquid chromatography tandem mass spectrometry method for simultaneous determination of sulfonamides, quinolones and benzimidazoles in bovine milk.

Development and validation of an ultra high performance liquid chromatography tandem mass spectrometry method for simultaneous determination of sulfonamides, quinolones and benzimidazoles in bovine milk.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-06-03)
Xiao-Lin Hou, Guo Chen, Li Zhu, Ting Yang, Jian Zhao, Lei Wang, Yin-Liang Wu
ABSTRACT

A simple, sensitive and reliable analytical method was developed for the simultaneous determination of 38 veterinary drugs (18 sulfonamides, 11 quinolones and 9 benzimidazoles) and 8 metabolites of benzimidazoles in bovine milk by ultra high performance liquid chromatography-positive electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS). Samples were extracted with acidified acetonitrile, cleaned up with Oasis(®) MCX cartridges, and analyzed by LC-MS/MS on an Acquity UPLC(®) BEH C18 column with gradient elution. The method allows such multi-analyte measurements within a 13min runtime while the specificity is ensured through the MRM acquisition mode. The method was validated according to the European Commission Decision 2002/657/EC determining specificity, decision limit (CCα), detection capability (CCβ), recovery, precision, linearity and stability. For compounds which have MRLs in bovine milk, the CCα values fall into a range from 11 to 115μg/kg, and the CCβ values fall within a range of 12-125μg/kg. For compounds which have not MRLs in bovine milk, the CCα values fall into a range from 0.01 to 0.08μg/kg, and the CCβ values fall within a range of 0.02-0.11μg/kg. The mean recoveries of the 46 analytes were between 87 and 119%. The calculated RSD values of repeatability and within-laboratory reproducibility experiments were below 11% and 15% for the 46 compounds, respectively. The method was demonstrated to be suitable for the simultaneous determination of sulfonamides, quinolones and benzimidazoles in bovine milk.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Methanol, NMR reference standard
Supelco
Albendazole sulfone, VETRANAL®, analytical standard
Sigma-Aldrich
Methanol, SAJ special grade
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (w/v) ammonium formate, 5 % (v/v) water, 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Methanol, SAJ first grade, ≥99.5%
Sigma-Aldrich
Methanol, JIS 300, ≥99.8%, for residue analysis
Sigma-Aldrich
Ammonium acetate solution, 50 % (w/v), for copper determination
Supelco
Fenbendazole, VETRANAL®, analytical standard
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, 99.93%
Supelco
Methanol, analytical standard
Sigma-Aldrich
Ammonium acetate solution, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
Ammonium acetate, 99.999% trace metals basis
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (v/v) trifluoroacetic acid
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Ammonium acetate, BioUltra, for molecular biology, ≥99.0%
Sigma-Aldrich
Ammonium acetate solution, for molecular biology, 7.5 M
Sigma-Aldrich
Fenbendazole, ≥98%
Supelco
Mebendazole, analytical standard, ≥98% (HPLC)
Sigma-Aldrich
Ammonium acetate, for molecular biology, ≥98%
Sigma-Aldrich
Ammonium acetate, reagent grade, ≥98%
Sigma-Aldrich
Ammonium acetate, BioXtra, ≥98%
Supelco
Norfloxacin-d5, VETRANAL®, analytical standard
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Acetonitrile solution, contains 10.0% acetone, 0.05% formic acid, 40.0% 2-propanol
Sigma-Aldrich
Methanol, JIS special grade, ≥99.8%
Sigma-Aldrich
Methanol, suitable for HPLC
Supelco
Ammonium acetate, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%