Skip to Content
Merck
  • Adrenocorticotropic hormone but not high-density lipoprotein cholesterol or salivary cortisol was a predictor of adrenal insufficiency in patients with septic shock.

Adrenocorticotropic hormone but not high-density lipoprotein cholesterol or salivary cortisol was a predictor of adrenal insufficiency in patients with septic shock.

Shock (Augusta, Ga.) (2014-03-29)
Josiane Festti, Cintia Magalhães Carvalho Grion, Luciana Festti, Tânia Longo Mazzuco, Helena Pantelion Lima-Valassi, Vinícius Nahime Brito, Décio Sabbatini Barbosa, Alexandre José Faria Carrilho
ABSTRACT

Relative adrenal insufficiency in sepsis has been extensively debated on; however, accurate diagnosis and therapeutic intervention remain controversial. The authors aimed to evaluate adrenocorticotropic hormone (ACTH), salivary cortisol, total cortisol and estimated plasma-free cortisol, cholesterol, and lipoproteins as predictors of adrenal insufficiency in patients within 24 h of septic shock diagnosis. This prospective study evaluated all hospitalized patients older than 18 years who developed septic shock and were using vasoactive drugs within 24 h of diagnosis. Blood and saliva samples were drawn at baseline and 60 min (T60) after 250 μg tetracosactide intravenous injection. Patients were divided into two groups: responders (Δ [T60 minus baseline] total cortisol >9 μg/dL) and nonresponders (Δ total cortisol ≤ 9 μg/dL or baseline total cortisol <10 μg/dL). The latter group was considered to have adrenal insufficiency. A total of 7,324 hospitalized patients were monitored, and 34 subjects with septic shock were included in the analysis. Adrenal insufficiency was found in 32.4%. Total cholesterol, high-density lipoprotein cholesterol, triglycerides, and salivary cortisol did not differ between groups. Estimated plasma-free cortisol was not better than total plasma cortisol in estimating adrenal function. Baseline endogenous ACTH was higher in nonresponders than responders (55.5 pg/mL vs. 18.3 pg/mL, respectively; P = 0.01). The cutoff ACTH value that discriminated patients with adrenal insufficiency was 31.5 pg/mL. Thus, endogenous ACTH measured within 24 h of septic shock diagnosis could predict adrenal response to tetracosactide.

MATERIALS
Product Number
Brand
Product Description

Supelco
Hydrocortisone, Pharmaceutical Secondary Standard; Certified Reference Material
Tetracosactide, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Hydrocortisone, γ-irradiated, powder, BioXtra, suitable for cell culture
Sigma-Aldrich
Hydrocortisone, ≥98% (HPLC)
Sigma-Aldrich
Hydrocortisone, meets USP testing specifications
Sigma-Aldrich
Hydrocortisone, BioReagent, suitable for cell culture
Hydrocortisone, European Pharmacopoeia (EP) Reference Standard
Hydrocortisone, British Pharmacopoeia (BP) Assay Standard
USP
Hydrocortisone, United States Pharmacopeia (USP) Reference Standard
Hydrocortisone for peak identification, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Adrenocorticotropic Hormone Fragment 1-24 human, rat, ≥97% (HPLC)