Skip to Content
Merck
  • High throughput quantification of prohibited substances in plasma using thin film solid phase microextraction.

High throughput quantification of prohibited substances in plasma using thin film solid phase microextraction.

Journal of chromatography. A (2014-12-03)
Nathaly Reyes-Garcés, Barbara Bojko, Janusz Pawliszyn
ABSTRACT

Simple, fast and efficient sample preparation approaches that allow high-throughput isolation of various compounds from complex matrices are highly desired in bioanalysis. Particularly sought are methods that can, without sacrificing time, easily remove matrix interferences capable of inducing ionization suppression/enhancement, or causing detrimental effects in instrumental performance. In this work, an automated high-throughput sample preparation method using thin film solid phase microextraction (SPME) for the analysis of multiple prohibited substances in plasma is proposed. A biocompatible SPME extraction phase made of hydrophilic-lipophilic balance particles immobilized with polyacrylonitrile (PAN) demonstrated satisfactory extraction capabilities for 25 compounds of a wide range of polarities (logP from -2 to 6.8). Due to the well-known biocompatible characteristics of PAN-based SPME coatings, minimum sample handling was required. Experimental conditions for pre-conditioning, extraction, wash and desorption were carefully optimized for the proposed method. By taking full advantage of the 96 thin film handling capability of the automated system, a preparation time of approximately 1.5min per sample can be achieved. Satisfactory results in terms of absolute matrix effects were found for the majority of the studied analytes, given that 24 out of 25 compounds exhibited values in the range of 100 and 120%. The method was validated in terms of linearity (R(2)>0.99), inter and intra-day accuracy (85-130%) and precision (<20%) and limits of quantitation (0.25-10ngmL(-1) for most compounds).

MATERIALS
Product Number
Brand
Product Description

Supelco
SPME fiber assembly, Carbowax-Polyethylene Glycol (PEG) Coating, needle size 23 ga, df 60 μm(PEG, metal alloy fiber, for use with manual holder
Supelco
SPME fiber assembly, Carbowax-Polyethylene Glycol (PEG) Coating, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
Phosphate Standard for IC, TraceCERT®, 1000 mg/L phosphate in water (nominal concentration)
Supelco
Prednisolone, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
N,N-Dimethylformamide, JIS special grade, ≥99.5%
Sigma-Aldrich
Potassium chloride solution, 0.01 M
Sigma-Aldrich
N,N-Dimethylformamide, SAJ first grade, ≥99.0%
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Sigma-Aldrich
Potassium chloride, tested according to Ph. Eur.
Sigma-Aldrich
Potassium chloride, BioUltra, for molecular biology, ≥99.5% (AT)
Supelco
Potassium chloride solution, conductance standard B acc. to ISO 7888, 0.01 M KCl
Supelco
Potassium chloride solution, conductance standard C acc. to ISO 7888, 0.001 M KCl
Sigma-Aldrich
Potassium chloride solution, BioUltra, for molecular biology, ~1 M in H2O
Supelco
Potassium chloride solution, conductance standard A acc. to ISO 7888, 0.1 M KCl
Supelco
Potassium chloride solution, for Ag/AgCl electrodes, ~3 M KCl, saturated with silver chloride
Supelco
ISA (ionic strength adjustment solution: 1 M KCl), 1 M KCl
Supelco
Prednisolone, VETRANAL®, analytical standard
Supelco
Potassium chloride solution, BioUltra, ~3 M in H2O
Sigma-Aldrich
Potassium chloride, 99.999% trace metals basis
Sigma-Aldrich
N,N-Dimethylformamide, anhydrous, 99.8%
Sigma-Aldrich
Divinylbenzene, technical grade, 80%
Supelco
N,N-Dimethylformamide, analytical standard
Sigma-Aldrich
Potassium chloride, AnhydroBeads, −10 mesh, 99.99% trace metals basis
Sigma-Aldrich
Divinylbenzene, technical grade, 55%
Sigma-Aldrich
N,N-Dimethylformamide, ACS reagent, ≥99.8%
Sigma-Aldrich
N,N-Diethylnicotinamide, 99%
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 30 μm(PDMS, needle size 24 ga, for use with autosampler
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder