RÉSUMÉ

Enhanced sensitivity for determination of basic drugs in body fluids was achieved by in-line coupling of extraction across supported liquid membrane (SLM) to large electrokinetic injection and transient isotachophoresis-capillary zone electrophoresis (tITP-CZE) in commercial CZE instrument. Twelve cm long tITP plug of 300mM ammonium acetate was formed in the separation capillary just before the electrokinetic injection of acceptor solution containing nortriptyline, haloperidol and loperamide extracted across the SLM. The tITP plug ensured efficient stacking and preconcentration of the injected basic drugs due to the tITP action of ammonium and the drugs were then separated by CZE using 5.2M acetic acid as background electrolyte. No interferences were observed from highly-abundant body fluid species (NaCl and human serum albumin) due to the excellent clean-up properties of SLMs and analytical sensitivity increased up to 340 times compared to SLM extractions coupled in-line to CZE with standard hydrodynamic injections. The SLM-tITP-CZE method was characterized by good repeatability (RSDs of peak areas below 7.8%), linearity over two orders of magnitude (r(2) better than 0.994) and limits of detection (defined as 3×S/N) between 3 and 45μg/L. Interfacing of SLM extractions to CZE instrumentation was achieved by low-cost, disposable micro-extraction devices, which can be routinely prepared in every analytical laboratory. These devices eliminated sample carry-over, minimized the need for manual sample handling and ensured fully automated determination (including extraction, injection, preconcentration and separation) of the three basic drugs in 20μL of untreated body fluids.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, for molecular biology
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Acide acétique, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Acide acétique, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, meets USP testing specifications
Sigma-Aldrich
Acétate d′ammonium, ACS reagent, ≥97%
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, for molecular biology
Sigma-Aldrich
Acétate d′ammonium, ≥99.99% trace metals basis
Sigma-Aldrich
Chlorure de sodium, for molecular biology, DNase, RNase, and protease, none detected, ≥99% (titration)
Sigma-Aldrich
Acide acétique, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Chlorure de sodium solution, 5 M in H2O, BioReagent, for molecular biology, suitable for cell culture
Sigma-Aldrich
Acide acétique solution, suitable for HPLC
Sigma-Aldrich
Chlorure de sodium solution, 0.9% in water, BioXtra, suitable for cell culture
Sigma-Aldrich
Chlorure de sodium, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99%
Sigma-Aldrich
Acide acétique, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, FCC, 99.8-100.5%
Sigma-Aldrich
Acide acétique, glacial, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8%
SAFC
Chlorure de sodium solution, 5 M
Sigma-Aldrich
Éthanol, purum, absolute ethanol, denaturated with 4.8% isopropanol, A15 IPA1, ≥99.8% (based on denaturant-free substance)
Sigma-Aldrich
Acétate d′ammonium, for molecular biology, ≥98%
Sigma-Aldrich
Acétate d′ammonium solution, for molecular biology, 7.5 M
Sigma-Aldrich
Chlorure de sodium solution, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
Chlorure de sodium, BioUltra, for molecular biology, ≥99.5% (AT)
Sigma-Aldrich
Chlorure de sodium, 99.999% trace metals basis
Sigma-Aldrich
Acide acétique, for luminescence, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
Éthanol, BioUltra, for molecular biology, ≥99.8%, (absolute alcohol, without additive, A15 o1)
USP
Acide acétique, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acétate d′ammonium, 99.999% trace metals basis
Sigma-Aldrich
Acide acétique, ≥99.5%, FCC, FG
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
Acide acétique, natural, ≥99.5%, FG