M-194
(±)-cis-3-Methylfentanyl hydrochloride solution
100 μg/mL in methanol (as free base), certified reference material, ampule of 0.5 mL, Cerilliant®
About This Item
Produits recommandés
Qualité
certified reference material
Niveau de qualité
Forme
liquid
Caractéristiques
Snap-N-Spike®/Snap-N-Shoot®
Conditionnement
ampule of 0.5 mL
Fabricant/nom de marque
Cerilliant®
drug control
estupefaciente (Spain); Decreto Lei 15/93: Tabela IA (Portugal)
Concentration
100 μg/mL in methanol (as free base)
Technique(s)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
Application(s)
forensics and toxicology
Format
single component solution
Température de stockage
−20°C
InChI
1S/C23H30N2O.ClH/c1-3-23(26)25(21-12-8-5-9-13-21)22-15-17-24(18-19(22)2)16-14-20-10-6-4-7-11-20;/h4-13,19,22H,3,14-18H2,1-2H3;1H/t19-,22+;/m0./s1
Clé InChI
GQIWDGKLQJBQJU-MGBOEYOKSA-N
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Description générale
Application
- HPLC-UV and GC-MS Methods for Determination of Chlorambucil and Valproic Acid in Plasma for Further Exploring a New Combined Therapy of Chronic Lymphocytic Leukemia.: This study employed the LiChrospher® 100 RP-18 endcapped (5µm) Hibar® RT 125-2 column for high-performance liquid chromatography analysis of chlorambucil and valproic acid in plasma. The method facilitated efficient separation and detection, critical for evaluating combined chemotherapy protocols (Lipska K et al., 2021).
- Application of chemometric approach for development and validation of high performance liquid chromatography method for estimation of ropinirole hydrochloride.: This research utilized the LiChrospher® 100 RP-18 endcapped (5µm) Hibar® RT 125-2 column to develop and validate a robust HPLC method for the quantification of ropinirole hydrochloride. The study demonstrated the column′s capability in achieving high sensitivity and precision in pharmaceutical analysis (Fatima S et al., 2019).
- Determination of retinol and retinyl esters in human plasma by high-performance liquid chromatography with automated column switching and ultraviolet detection.: The LiChrospher® 100 RP-18 endcapped (5µm) Hibar® RT 125-2 column was applied in the analysis of retinol and its esters in human plasma. This study showcased the column′s efficiency in separating closely related compounds, essential for accurate biochemical assays (Hartmann S et al., 2001).
- Rapid, highly sensitive method for the determination of morphine and its metabolites in body fluids by liquid chromatography-mass spectrometry.: This investigation leveraged the LiChrospher® 100 RP-18 endcapped (5µm) Hibar® RT 125-2 column to develop a sensitive LC-MS method for morphine and its metabolites. The column′s performance ensured reliable detection in forensic and clinical toxicology (Schänzle G et al., 1999).
- Determination of 13-cis-3-hydroxyretinoic acid, all-trans-3-hydroxyretinoic acid and their 4-oxo metabolites in human and animal plasma by high-performance liquid chromatography with automated column switching and UV detection.: This study used the LiChrospher® 100 RP-18 endcapped (5µm) Hibar® RT 125-2 column for the simultaneous analysis of retinoic acid metabolites, highlighting its application in pharmacokinetics and metabolism research (Wyss R et al., 1998).
- Determination of endogenous levels of 13-cis-retinoic acid (isotretinoin), all-trans-retinoic acid (tretinoin) and their 4-oxo metabolites in human and animal plasma by high-performance liquid chromatography with automated column switching and ultraviolet detection.: The research focused on using the LiChrospher® 100 RP-18 endcapped (5µm) Hibar® RT 125-2 column for analyzing endogenous retinoic acids in plasma, demonstrating the column′s utility in clinical biochemistry and toxicology studies (Wyss R et al., 1997).
Informations légales
Produit(s) apparenté(s)
Mention d'avertissement
Danger
Mentions de danger
Conseils de prudence
Classification des risques
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
Organes cibles
Eyes
Code de la classe de stockage
3 - Flammable liquids
Classe de danger pour l'eau (WGK)
WGK 2
Point d'éclair (°F)
49.5 °F - closed cup
Point d'éclair (°C)
9.7 °C - closed cup
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique