Accéder au contenu
Merck

Anti-epidermal growth factor receptor conjugated mesoporous zinc oxide nanofibers for breast cancer diagnostics.

Nanoscale (2015-03-27)
Md Azahar Ali, Kunal Mondal, Chandan Singh, Bansi Dhar Malhotra, Ashutosh Sharma
RÉSUMÉ

We report the fabrication of an efficient, label-free, selective and highly reproducible immunosensor with unprecedented sensitivity (femto-molar) to detect a breast cancer biomarker for early diagnostics. Mesoporous zinc oxide nanofibers (ZnOnFs) are synthesized by electrospinning technique with a fiber diameter in the range of 50-150 nm. Fragments of ZnOnFs are electrophoretically deposited on an indium tin oxide glass substrate and conjugated via covalent or electrostatic interactions with a biomarker (anti-ErbB2; epidermal growth factor receptor 2). Oxygen plasma treatment of the carbon doped ZnOnFs generates functional groups (-COOH, -OH, etc.) that are effective for the conjugation of anti-ErbB2. ZnOnFs without plasma treatment that conjugate via electrostatic interactions were also tested for comparison. Label-free detection of the breast cancer biomarker by this point-of-care device is achieved by an electrochemical impedance technique that has high sensitivity (7.76 kΩ μM(-1)) and can detect 1 fM (4.34 × 10(-5) ng mL(-1)) concentration. The excellent impedimetric response of this immunosensor provides a fast detection (128 s) in a wide detection test range (1.0 fM-0.5 μM). The oxy-plasma treated ZnOnF immunoelectrode shows a higher association constant (404.8 kM(-1) s(-1)) indicating a higher affinity towards the ErbB2 antigen compared to the untreated ZnOnF immunoelectrode (165.6 kM(-1) s(-1)). This sensor is about an order of magnitude more sensitive than the best demonstrated in the literature based on different nanomaterials and about three orders of magnitude better than the ELISA standard for breast cancer biomarker detection. This proposed point-of-care cancer diagnostic offers several advantages, such as higher stability, rapid monitoring, simplicity, cost-effectiveness, etc., and should prove to be useful for the detection of other bio- and cancer markers.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Glycérol, ACS reagent, ≥99.5%
Sigma-Aldrich
Glycérol, for molecular biology, ≥99.0%
Sigma-Aldrich
Glycérol, ReagentPlus®, ≥99.0% (GC)
Sigma-Aldrich
1,2-Dichloroéthane, ACS reagent, ≥99.0%
Sigma-Aldrich
N-Hydroxysuccinimide, 98%
Sigma-Aldrich
Glycérol solution, 83.5-89.5% (T)
Sigma-Aldrich
Glycérol, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for electrophoresis, ≥99% (GC)
Sigma-Aldrich
Glycérol, BioUltra, for molecular biology, anhydrous, ≥99.5% (GC)
Sigma-Aldrich
Naphthalene, 99%
USP
Glycérine, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Glycérol, FCC, FG
Sigma-Aldrich
Anthracene, ReagentPlus®, 99%
Sigma-Aldrich
Anthracene, reagent grade, 97%
Sigma-Aldrich
Glycérol, ≥99.5%
Sigma-Aldrich
Naphthalene, suitable for scintillation, ≥99%
Sigma-Aldrich
1,2-Dichloroéthane, anhydrous, 99.8%
Sigma-Aldrich
Glycérol, BioXtra, ≥99% (GC)
Sigma-Aldrich
Anthracene, suitable for scintillation, ≥99.0% (GC)
Sigma-Aldrich
Glycérine, meets USP testing specifications
Supelco
Naphthalene, analytical standard
Supelco
Anthracene, analytical standard
Supelco
Glycérol, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Naphthalene, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Glycérol, Vetec, reagent grade, 99%
Supelco
Glycérol, analytical standard
Supelco
Anthracene, analytical standard
Supelco
1,2-Dichloroéthane, analytical standard
Sigma-Aldrich
Glycérol, tested according to Ph. Eur., anhydrous
Sigma-Aldrich
Anthracene, sublimed grade, ≥99%
Sigma-Aldrich
N-Hydroxysuccinimide, purum, ≥97.0% (T)