Accéder au contenu
Merck
  • Polydimethylsiloxane/metal-organic frameworks coated stir bar sorptive extraction coupled to high performance liquid chromatography-ultraviolet detector for the determination of estrogens in environmental water samples.

Polydimethylsiloxane/metal-organic frameworks coated stir bar sorptive extraction coupled to high performance liquid chromatography-ultraviolet detector for the determination of estrogens in environmental water samples.

Journal of chromatography. A (2013-09-03)
Cong Hu, Man He, Beibei Chen, Cheng Zhong, Bin Hu
RÉSUMÉ

In this work, three kinds of metal-organic frameworks (MOFs), MOF-5, MOF-199 and IRMOF-3, were introduced in stir bar sorptive extraction (SBSE) and novel polydimethylsiloxane (PDMS)/MOFs (including PDMS/MOF-5, PDMS/MOF-199 and PDMS/IRMOF-3) coated stir bars were prepared by sol-gel technique. These PDMS/MOFs coatings were characterized and critically compared for the extraction of seven target estrogens (17-β-estradiol, dienestrol, diethylstilbestrol, estrone, 4-t-octylphenol, bisphenol-A and 17α-ethynylestradiol) by SBSE, and the results showed that PDMS/IRMOF-3 exhibited highest extraction efficiency. Based on the above facts, a novel method of PDMS/IRMOF-3 coating SBSE-high performance liquid chromatography ultraviolet (HPLC-UV) detection was developed for the determination of seven target estrogens in environmental waters. Several parameters affecting extraction of seven target estrogens by SBSE (PDMS/IRMOF-3) including extraction time, stirring rate, pH, ionic strength, desorption solvent and desorption time were investigated. Under the optimal experimental conditions, the limits of detection (LODs, S/N=3) were found to be in the range of 0.15-0.35 μg/L. The linear range was 2-2,500 μg/L for 17α-ethynylestradiol and 1-2,500 μg/L for other estrogens. The relative standard deviations (RSDs) were in the range of 3.7-9.9% (n=8, c=20 μg/L) and the enrichment factors were from 30.3 to 55.6-fold (theoretical enrichment factor was 100-fold). The proposed method was successfully applied to the analysis of estrogens in environmental water samples, and quantitative recoveries were obtained for the spiking experiments.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Huile de silicone, viscosity 10 cSt (25 °C)
Sigma-Aldrich
Huile de silicone, viscosity 5 cSt (25 °C)
Sigma-Aldrich
Huile de silicone, viscosity 20 cSt (25 °C)
Sigma-Aldrich
Huile de silicone, viscosity 100 cSt (25 °C)
Sigma-Aldrich
Huile de silicone, viscosity 1,000 cSt (25 °C)
Sigma-Aldrich
Huile de silicone, viscosity 350 cSt (25 °C)
Sigma-Aldrich
Huile de silicone, viscosity 500 cSt (25 °C)
Sigma-Aldrich
Huile de silicone, viscosity 50 cSt (25 °C)
Sigma-Aldrich
Huile de silicone, viscosity 10,000 cSt (25 °C)
Sigma-Aldrich
Huile de silicone, for oil baths (from −50°C to +200°C)
Sigma-Aldrich
Huile de silicone, viscosity 100,000 cSt (25 °C)
Sigma-Aldrich
Huile de silicone, viscosity 60,000 cSt (25 °C)
Sigma-Aldrich
Huile de silicone, viscosity 30,000 cSt (25 °C)
Huile de silicone, for melting point and boiling point apparatuses