Accéder au contenu
Merck
Toutes les photos(2)

Key Documents

GF93990628

Tantalum

tube, 500mm, outside diameter 0.80mm, inside diameter 0.50mm, wall thickness 0.15mm, as drawn, 99.9%

Synonyme(s) :

Tantalum, TA007055, Ta

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule empirique (notation de Hill):
Ta
Numéro CAS:
Poids moléculaire :
180.95
Numéro MDL:
Code UNSPSC :
12141741
ID de substance PubChem :
Nomenclature NACRES :
NA.23

Pression de vapeur

<0.01 mmHg ( 537.2 °C)

Pureté

≥99.9%

Forme

tubes

Température d'inflammation spontanée

572 °F

Fabricant/nom de marque

Goodfellow 939-906-28

Résistivité

13.5 μΩ-cm, 20°C

Point d'ébullition

5425 °C (lit.)

Pf

2996 °C (lit.)

Densité

16.69 g/cm3 (lit.)

Chaîne SMILES 

[Ta]

InChI

1S/Ta

Clé InChI

GUVRBAGPIYLISA-UHFFFAOYSA-N

Description générale

For updated SDS information please visit www.goodfellow.com.

Informations légales

Product of Goodfellow

Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Xiao-kang Tang et al.
Zhongguo gu shang = China journal of orthopaedics and traumatology, 26(7), 617-620 (2013-10-19)
Incorrect treatment for femur head necrosis can cause collapse of femoral head and tresult in severe harm for the patients (especially for the patient with middle-aged and young). The structure and mechanics characteristics of tantalum rod is similar to bone
Ulrich Dorn et al.
The Journal of arthroplasty, 29(4), 831-835 (2013-10-09)
This study compared the corrosion behavior of tantalum-coated cobalt-chromium modular necks with that of titanium alloy modular necks at their junction to titanium-alloy femoral stem. Tests were performed in a dry assembly and two wet assemblies, one contaminated with calf
[Tantalum dust as a contrast substance for laryngography and bronchography (a review of the literature)].
R M Rabinovich
Vestnik rentgenologii i radiologii, (1)(1), 77-79 (1981-01-01)
Clinical use of porous tantalum in complex primary total knee arthroplasty.
Neil P Sheth et al.
American journal of orthopedics (Belle Mead, N.J.), 38(10), 526-530 (2009-12-17)
Nilesh Patil et al.
Journal of biomedical materials research. Part B, Applied biomaterials, 89(1), 242-251 (2008-10-08)
Conventional porous-coated joint prostheses used in hip and knee reconstruction have demonstrated good clinical results, however, these implants possess some inherent shortcomings such as low volumetric porosity, suboptimal frictional characteristics, and higher modulus of elasticity relative to that of bone.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique