Skip to Content
Merck

Decoys for docking.

Journal of medicinal chemistry (2005-05-27)
Alan P Graves, Ruth Brenk, Brian K Shoichet
ABSTRACT

Molecular docking is widely used to predict novel lead compounds for drug discovery. Success depends on the quality of the docking scoring function, among other factors. An imperfect scoring function can mislead by predicting incorrect ligand geometries or by selecting nonbinding molecules over true ligands. These false-positive hits may be considered "decoys". Although these decoys are frustrating, they potentially provide important tests for a docking algorithm; the more subtle the decoy, the more rigorous the test. Indeed, decoy databases have been used to improve protein structure prediction algorithms and protein-protein docking algorithms. Here, we describe 20 geometric decoys in five enzymes and 166 "hit list" decoys-i.e., molecules predicted to bind by our docking program that were tested and found not to do so-for beta-lactamase and two cavity sites in lysozyme. Especially in the cavity sites, which are very simple, these decoys highlight particular weaknesses in our scoring function. We also consider the performance of five other widely used docking scoring functions against our geometric and hit list decoys. Intriguingly, whereas many of these other scoring functions performed better on the geometric decoys, they typically performed worse on the hit list decoys, often highly ranking molecules that seemed to poorly complement the model sites. Several of these "hits"from the other scoring functions were tested experimentally and found, in fact, to be decoys. Collectively, these decoys provide a tool for the development and improvement of molecular docking scoring functions. Such improvements may, in turn, be rapidly tested experimentally against these and related experimental systems, which are well-behaved in assays and for structure determination.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Ethylbenzene solution, NMR reference standard, 10% in chloroform-d (99.8 atom % D)
Supelco
Propylbenzene, analytical standard
Sigma-Aldrich
Propylbenzene, ≥99.0% (GC)
Supelco
m-Xylene, analytical standard
Supelco
2-Fluoroaniline, ≥99%
Sigma-Aldrich
Indole, ≥99%
Sigma-Aldrich
Ethylbenzene solution, NMR reference standard, 0.1% in chloroform-d (99.8 atom % D), TMS 0.01 %, NMR tube size 10 mm × 8 in.
Sigma-Aldrich
Butylbenzene, ≥99%
Sigma-Aldrich
2-Ethyltoluene, 99%
Sigma-Aldrich
3-Ethyltoluene, 99%
Sigma-Aldrich
Thianaphthene, 98%
Supelco
Ethylbenzene solution, NMR reference standard, 0.1% in chloroform-d (99.8 atom % D), TMS 0.01 %, NMR tube size 5 mm × 8 in.
Sigma-Aldrich
Ethylbenzene solution, NMR reference standard, 0.1% in chloroform-d (99.8 atom % D), TMS 0.01 %, NMR tube size 8 mm × 8 in.
Sigma-Aldrich
Ethylbenzene solution, NMR reference standard, 5% in chloroform-d (99.8 atom % D), TMS 2 %, NMR tube size 5 mm × 8 in.
Supelco
Butylbenzene, analytical standard
Sigma-Aldrich
Indole, ≥99%, FG
Sigma-Aldrich
Propylbenzene, 98%
Sigma-Aldrich
m-Xylene, anhydrous, ≥99%
Sigma-Aldrich
Thianaphthene, 95%
Sigma-Aldrich
Ethylbenzene solution, NMR reference standard, 0.1% in chloroform-d (99.8 atom % D), TMS 0.01 %, NMR tube size 5 mm × 8 in. , ultra-thin wall
Sigma-Aldrich
m-Xylene, ReagentPlus®, 99%
Sigma-Aldrich
m-Xylene, puriss. p.a., ≥99.0% (GC)
Sigma-Aldrich
Toluene, suitable for HPLC, ≥99.9%
Sigma-Aldrich
4-Ethyltoluene, technical grade, 90%
Sigma-Aldrich
4-Ethyltoluene, ≥95.0% (GC)
Supelco
o-Xylene, analytical standard
Supelco
p-Xylene, analytical standard
Sigma-Aldrich
3-Chlorophenol, 98%
Supelco
Phenol solution, 5000 μg/mL in methanol, certified reference material
Sigma-Aldrich
o-Xylene, anhydrous, 97%