Separation Options with Superdex®
Superdex® is produced with different average particle sizes and different selectivities (see Table 2.2).
- Use the prepacked columns with Superdex® Peptide, Superdex® 75, and Superdex® 200 Increase for small-scale preparative purification and analytical runs.
- Use columns prepacked with Superdex® 30 prep grade, Superdex® 75 prep grade, or Superdex® 200 prep grade media for preparative applications.
- Use bulk media of Superdex® 30 prep grade, Superdex® 75 prep grade, and Superdex® 200 prep grade for preparative purification with larger sample volumes of up to 13 mL.
- The maximum pressure drop over the packed bed is a typical value. Note that the actual value is individual for each column and needs to be determined (see Setting column pressure limits, Chapter 1).
- Start with Superdex® 200 Increase when the molecular weight of the protein of interest is unknown. Superdex® 200 Increase or Superdex® 200 prep grade are especially suitable for the separation of monoclonal antibodies from dimers and from contaminants of lower molecular weight, for example albumin and transferrin.
- Start with Superdex® Peptide or Superdex® 30 prep grade for separations of peptides, oligonucleotides and small proteins below Mr 10 000.
- Exposure to temperatures outside the range 4 °C to 40 °C will negatively affect the efficiency of the packed bed and the column will need to be repacked.
Product* | Fractionation range, Mr (globular proteins) | Sample Loading capacity† | Maximum pressure drop over the packed bed | Recommended Operational Flow rate‡ |
---|---|---|---|---|
Superdex® 200 Increase 3.2/300 | 1 × 104 to 6 × 105 | 4 to 50 μL | 3.0 MPa, 30 bar, 435 psi** | 0.075 mL/min |
Superdex® 200 Increase 5/150 GL | 1 × 104 to 6 × 105 | 4 to 50 μL | 3.0 MPa, 30 bar, 435 psi** | 0.45 mL/min |
Superdex® 200 Increase 10/300 GL | 1 × 104 to 6 × 105 | 25 to 500 μL | 3.0 MPa, 30 bar, 435 psi** | 0.075 mL/min |
Superdex® Peptide 3.2/300 | 1 × 102 to 7 × 103 | < 50 μL | 2.0 MPa, 20 bar, 290 psi | 0.05 mL/min |
Superdex® Peptide 10/300 GL | 1 × 102 to 7 × 103 | 25 to 500 μL | 2.0 MPa, 20 bar, 290 psi | < 1.0 mL/min |
HiLoad 16/600 Superdex® 30 pg§ | < 1 × 104 | ≤ 5 mL | 3 MPa, 3 bar, 42 psi | 1.0 mL/min |
HiLoad 26/600 Superdex® 30 pg§ | < 1 × 104 | ≤ 13 mL | 3 MPa, 3 bar, 42 psi | 2.6 mL/min |
Superdex® 30 pg§ (Bulk medium) | < 1 × 104 | 0.5% to 4% of total column volume | Column-dependent | 10 to 50 cm/h |
Superdex® 75 3.2/300 | 3 × 103 to 7 × 104 | < 50 μL | 2.4 MPa, 24 bar, 350 psi | 0.05 mL/min |
Superdex® 75 5/150 GL | 3 × 103 to 7 × 104 | 4 to 50 μL | 1.8 MPa, 18 bar, 260 psi | 0.3 mL/min |
Superdex® 75 10/300 GL | 3 × 103 to 7 × 104 | 25 to 500 μL | 1.8 MPa, 18 bar, 260 psi | 0.5 to 0.75 mL/min |
HiLoad 16/600 Superdex® 75 pg§ | 3 × 103 to 7 × 104 | ≤ 5 mL | 0.3 MPa, 3 bar, 42 psi | 1.0 mL/min |
HiLoad 26/600 Superdex® 75 pg§ | 3 × 103 to 7 × 104 | ≤ 13 mL | 0.3 MPa, 3 bar, 42 psi | 2.6 mL/min |
Superdex® 75 pg§ (Bulk medium) | 3 × 103 to 7 × 104 | 0.5% to 4% of total column volume | Column-dependent | 10 to 50 cm/h |
Superdex® 200 3.2/300 | 1 × 104 to 6 × 105 | < 50 μL | 1.5 MPa, 15 bar, 220 psi | 0.05 mL/min |
Superdex® 200 5/150 GL | 1 × 104 to 6 × 105 | 4 to 50 μL | 1.5 MPa, 15 bar, 220 psi | 0.3 mL/min |
Superdex® 200 10/300 GL | 1 × 104 to 6 × 105 | 25 to 500 μL | 1.5 MPa, 15 bar, 220 psi | 0.5 to 0.75 mL/min |
HiLoad 16/600 Superdex® 200 pg§ | 1 × 104 to 6 × 105 | ≤ 5 mL | 0.3 MPa, 3 bar, 42 psi | 1.0 mL/min |
HiLoad 26/600 Superdex® 200 pg§ | 1 × 104 to 6 × 105 | ≤ 13 mL | 0.3 MPa, 3 bar, 42 psi | 2.6 mL/min |
Superdex® 200 pg§ (Bulk medium) | 1 × 104 to 6 × 105 | 0.5% to 4% of total column volume | Column-dependent | 10 to 50 cm/h |