Saltar al contenido
Merck

LC/MS/MS of Pesticides in Oranges on Ascentis® Express C18 after Sample Prep using Supel Que Z-Sep/C18 QuEChERS sorbent

LC/MS/MS of Pesticides in Oranges on Ascentis® Express C18 after Sample Prep using Supel™ Que Z-Sep/C18 QuEChERS sorbent application for HPLC

Materiales

Producto relacionado

Referencia del producto
Descripción
Precios

Supel QuE

Empty Centrifuge Tube with Lid, centrifuge tube volume 50 mL, pk of 50, suitable for EN 15662:2008 per BS

Supel QuE

PSA Tube, pack of 100, AOAC® 2007.01

Supel QuE

PSA/C18 Tube, pack of 100, AOAC® 2007.01

columna analítica

Referencia del producto
Descripción
Precios

Columna para HPLC Ascentis® Express C18, 2,7 μm

2.7 μm particle size, L × I.D. 5 cm × 2.1 mm

patrón

Referencia del producto
Descripción
Precios

Mecarbam

PESTANAL®, analytical standard

2-Octyl-4-isothiazolin-3-one

PESTANAL®, analytical standard

Aldicarb

PESTANAL®, analytical standard

Etrimfos

PESTANAL®, analytical standard

Fenoxycarb

PESTANAL®, analytical standard

Trichlorfon

PESTANAL®, analytical standard

Iprobenfos

PESTANAL®, analytical standard

Terbufos

PESTANAL®, analytical standard

Phosmet

PESTANAL®, analytical standard

EPN

PESTANAL®, analytical standard

Dibrom®

PESTANAL®, analytical standard

Parathion-methyl

PESTANAL®, analytical standard

Pyraclostrobin

PESTANAL®, analytical standard

Spiromesifen

PESTANAL®, analytical standard

Flufenoxuron

PESTANAL®, analytical standard

Fenpyroximate

PESTANAL®, analytical standard

Lufenuron

PESTANAL®, analytical standard

Fenhexamid

PESTANAL®, analytical standard

Tolclofos-methyl

PESTANAL®, analytical standard

tubo o placa de SPE

Referencia del producto
Descripción
Precios

Supel QuE

Citrate Extraction Tube, pk of 50, suitable for EN 15662

Supel QuE

Z-Sep/C18 Tube, centrifuge tube volume 2 mL, pack of 100

CONDITIONS

sample preparation

Dispersive (QuEChERS)

sample/matrix

10 g of pureed oranges (homogenized with rind); spike at 50 ppb (add 16.75 μL of a custom made pesticide mix, each analyte at 30 μg/mL)

extraction tube

Supel QuE Citrate (EN) Tube (55227-U)

extraction process

add 10 mL acetonitrile; shake for 1 minute; add contents of a Supel QuE citrate extraction tube (55227-U); shake immediately for 1 minute; centrifuge at 3200 rpm for 5 minutes

clean-up tube

Supel-Q PSA/C18 (55284-U)

clean-up process

transfer 0.7 mL of the acetonitrile layer into a Supel QuE Z-Sep/C18 cleanup tube (55284-U); shake for 1 minute; centrifuge at 5000 rpm for 5 minutes; (transfer 0.2 mL of the supernatant into an empty 1.5 mL centrifuge tube; add 0.2 mL of water; centrifuge at 5000 rpm for 2 minutes.)

column

Ascentis Express C18, 5 cm x 2.1 mm I.D., 2.7 μm particles (53822-U)

mobile phase

[A] 10 mM ammonium acetate in water; [B] 10 mM ammonium acetate in acetonitrile

gradient

Hold at 30% B for 1 min; 30% to 80% B in 2 min; hold at 80% B for 4 min; hold at 100% B for 3 min; hold at 30% B for 3 min

flow rate

0.3 mL/min

pressure

2730 psi (188 bar)

column temp.

30 °C

detector

MS/MS, ESI positive

Descripción

Nota de análisis

This demonstrates the application of the Z-Sep/C18 sorbent to the cleanup of fruits in the LC-MS-MS analysis of polar pesticides including organophosphates, carbamates and benzoylureas
Sample pretreatment: 10 g of pureed oranges homogenized with rind; spike at 50 ppb by adding 16.75 μL of a pesticide mix containing each analyte at 30 μg/mL

Información legal

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany
Supel is a trademark of Sigma-Aldrich Co. LLC
null