- Adsorption of water vapour from humid air in carbon molecular sieves: carbosieve S-III and carboxens 569, 1000 and 1001.
Adsorption of water vapour from humid air in carbon molecular sieves: carbosieve S-III and carboxens 569, 1000 and 1001.
The Analyst (2003-03-11)
Patrycja Fastyn, Wojciech Kornacki, Malgorzata Kardaś, Janusz Gawlowski, Jan Niedzielski
PMID12625564
RESUMEN
The adsorption of water vapour in carbon molecular sieves (CMS) used to determine volatile organic compounds (VOCs) in air was investigated. The CMS mass in the trap was found not to affect the mass of retained water under conditions of incomplete saturation of the adsorbent bed with water. Thus, the restrictions commonly imposed on the CMS mass are not necessary. The usefulness of four different CMSs to sample large volumes of humid air was estimated. Carboxen 1000 exhibited the best performance. To assess the magnitude of CMS mass in the trap in dependence on the volume, the relative humidity and the temperature of the sample, the use of a novel parameter, called the water vapour interference factor, was suggested.
MATERIALES
Referencia del producto
Marca
Descripción del producto
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, matrix active group 50/30µm DVB/CAR/PDMS, needle size 24 ga, StableFlex fiber, for use with autosampler, fiber L 2 cm, pk of 3
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, matrix active group 50/30µm DVB/CAR/PDMS, StableFlex fiber, manual holder, needle size 24 ga
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, 50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, plain gray hub
Supelco
ORBO™ 90 Carboxen® 564 (20/45) 160/80 mg, W,F,F separators, O.D. × L 6 mm × 75 mm, pkg of 25 ea, for analyte group MEK (methylethyl ketone)
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, matrix active group 50/30µm DVB/CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler, fiber L 1 cm, pk of 3
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, 50/30µm DVB/CAR/PDMS, StableFlex (2cm), needle size 23 ga, Autosampler, pk of 3, notched gray hub
Supelco
Columna capilar para GC Carboxen®-1010 PLOT, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
Columna capilar para GC Carboxen®-1006 PLOT, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Columna capilar para GC Carboxen®-1010 PLOT, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
Columna capilar para GC Carboxen®-1006 PLOT, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, for use with autosampler, matrix active group 50/30µm DVB/CAR/PDMS, needle size 23 ga, metal alloy fiber, fiber L 2 cm
Supelco
Tenax® TA / Carboxen® 1018, glass TD tube, preconditioned, O.D. × L 1/4 in. × 3 1/2 in., Sealed with (Swagelok® End-Fittings), pkg of 10 ea
Supelco
Tubo absorbente ORBO™-93, ORBO tube I.D. × L 6 mm × 95 mm, Bed A 180 mg, Bed B 90 mg, 60/80 mesh, pkg of 25 ea
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, matrix active group 50/30µm DVB/CAR/PDMS, needle size 23 ga, metal alloy fiber, for use with autosampler, fiber L 1 cm, pkg of 1 × ea