KVSSA10HH1

Millipore

Multimedia Durapore® 0,5/0,2/0,22 µm, Opticap® XL Cápsula

Opticap® XL 10, inlet connection diam. 9/16 in., pore size 0.5/0.2/0.22 μm, cartridge nominal length 10 in. (25 cm)

Sinónimos:

Opticap Sterilizing Grade XL10 Multimedia 0.5/0.2/0.22 μm 9/16 in. HB/HB

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
23151806

Materiales

PVDF
mixed cellulose esters (MCE)
mixed cellulose esters (MCE) prefilter
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
silicone seal

Nivel de calidad

cumplimiento norm.

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

esterilidad

non-sterile

Compatibilidad de esterilización

autoclavable compatible

Línea del producto

Opticap® XL 10

Características

hydrophilic

fabricante / nombre comercial

Opticap®

Parámetros

≤10.8 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.8 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C (Reverse; intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
80 psig max. inlet pressure
80 °C max. temp.

técnicas

bioburden reduction: suitable

Longitud

13.2 in.

Anchura

4.2 in.

longitud nominal del cartucho

10 in. (25 cm)

Diámetro

10.7 cm (4.2 in.)

filtración área

0.56 m2

diám. conexión a entrada

9/16 in.

diám. conexión a salida

9/16 in.

impurezas

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

extraíbles gravimétricos

≤75 mg/capsule

matriz

Multimedia Durapore®

pore size

0.5/0.2/0.22 μm pore size

entrada

sample type liquid

punto de burbuja

≥3450 mbar (50 psig), air with water at 23 °C

Adaptador

1/4 in. drain/vent hose barb (with double O-ring Seal)
(14 mm (9/16 in.) Hose Barb Inlet and Outlet)

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

Device Configuration: Capsule

Envase

Double Easy-Open bag

Otras notas

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Ligadura / enlace

Replaces: SN2M012A99

Nota de preparación

Sterilization Method
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Nota de análisis

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Gravimetric Extractables: after 24 hours in water at controlled room temperature
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L

Información legal

ASTM is a registered trademark of American Society for Testing and Materials
Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Cláusula de descargo de responsabilidad

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

¿No encuentra el producto adecuado?  

Pruebe nuestro Herramienta de selección de productos.

Código de clase de almacenamiento

4.1B - Flammable solid hazardous materials

Clase de riesgo para el agua (WGK)

WGK 3


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico