Skip to Content
Merck
All Photos(3)

Key Documents

10771

Sigma-Aldrich

Histopaque®-1077

Histopaque®-1077

sterile-filtered, density: 1.077

Sign Into View Organizational & Contract Pricing

Select a Size

100 ML
€57.70
6 X 100 ML
€194.00
500 ML
€199.00

€57.70


Estimated to ship onApril 17, 2025Details


Request a Bulk Order

Select a Size

Change View
100 ML
€57.70
6 X 100 ML
€194.00
500 ML
€199.00

About This Item

UNSPSC Code:
12352207
NACRES:
NA.75

€57.70


Estimated to ship onApril 17, 2025Details


Request a Bulk Order

sterility

sterile-filtered

Quality Level

form

liquid

shelf life

Expiry date on the label.

technique(s)

cell culture | mammalian: suitable

impurities

endotoxin, tested

density

1.077

application(s)

hematology
histology

storage temp.

2-8°C

General description

Histopaque-1077 is a sterile, endotoxin tested, ready-to-use medium. The Histopaque composition includes polysucrose and sodium diatrizoate, adjusted to a relative density of 1.077g/mL. This ready-to-use medium facilitates rapid recovery of viable lymphocytes and other mononuclear cells from small volumes of whole blood or bone marrow.

Application

Histopaque-1077 has been used for:
  • human lymphocyte antigen (HLA) typing
  • initial isolation step prior to the enumeration of T, B, and ‘null’ lymphocytes.
  • preparation of pure lymphocyte suspensions for cell culture and cytotoxicity assays.
  • isolation and purification of peripheral blood mononuclear cells (PBMCs) and bone marrow mononuclear cells (BMMCs)[1]
  • isolation of human lymphocytes[2]
  • isolation of breast cancer circulating tumor cells (CTCs) from the whole blood[3]
  • Histopaque-1077 is used in conjunction with Histopaque-1119 as it facilitates the rapid recovery of viable mononuclear cells and granulocytes from small volumes of whole blood

Features and Benefits

Histopaque®-1077 offers numerous advantages, such as:
  • Optimal recovery of viable cells
  • Permits selective separation of blood cell types
  • Prevents cell distortion
  • Preserves cell viability
  • Minimal extraneous cell interference
  • Reproducible performance from batch to batch
  • Sterile-filtered and endotoxin-tested
  • Stable at 2-8°C for at least 2 years when protected from light

Principle

Anticoagulated blood is layered onto Histopaque-1077. During centrifugation, erythrocytes are aggregated by polysucrose and rapidly sediment. Granulocytes become slightly hypertonic, which increases their sedimentation rate, resulting in pelleting at the bottom of the centrifuge tube. Lymphocytes and other mononuclear cells remain at the plasma/ Histopaque-1077 interface.

Legal Information

Histopaque is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictograms

Health hazard

Signal Word

Danger

Hazard Statements

Hazard Classifications

Resp. Sens. 1 - Skin Sens. 1

Storage Class Code

12 - Non Combustible Liquids

WGK

WGK 3


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Erin E Thacker et al.
Vaccine, 27(50), 7116-7124 (2009-09-30)
Targeting viral vectors encoding tumor-associated antigens to dendritic cells (DCs) in vivo is likely to enhance the effectiveness of immunotherapeutic cancer vaccines. We have previously shown that genetic modification of adenovirus (Ad) 5 to incorporate CD40 ligand (CD40L) rather than
Evaluation of respiration with clark type electrode in isolated mitochondria and permeabilized animal cells.
Silva AM and Oliveira PJ
Methods in Molecular Biology, 810, 7-24 (2012)
Ana C Leal et al.
Scientific reports, 7(1), 6438-6438 (2017-07-27)
Cancer patients are at an increased risk of developing thromboembolic complications. Several mechanisms have been proposed to explain cancer-associated thrombosis including the release of tumor-derived extracellular vesicles and the activation of host vascular cells. It was proposed that neutrophil extracellular
Romain A Colas et al.
Journal of immunology (Baltimore, Md. : 1950), 197(11), 4444-4452 (2016-11-02)
Maresin 1 (MaR1) is an immunoresolvent that governs resolution of acute inflammation, and its local metabolism in the context of infectious inflammation is of interest. In this study, we investigated the MaR1 metabolome in infectious exudates and its bioactions in
Maria Björkqvist et al.
The Journal of experimental medicine, 205(8), 1869-1877 (2008-07-16)
Huntington's disease (HD) is an inherited neurodegenerative disorder characterized by both neurological and systemic abnormalities. We examined the peripheral immune system and found widespread evidence of innate immune activation detectable in plasma throughout the course of HD. Interleukin 6 levels

Articles

Centrifugation enables the separation of particles by sedimentation. Learn how to separate particles using a centrifuge and how to use Stokes' law to calculate the velocity of sedimentation.

Protocols

This troubleshooting guide addresses the most common sources of error observed when using Histopaque but is not meant to be a comprehensive list.

Ficoll 400® is a non-ionic polymer with high hydrophilicity and water solubility, suitable for various biological applications.

Questions

1–10 of 21 Questions  
  1. Hello, we had a problem with the refrigerator leading the temperature increasing to 44 degrees Celsius for over the 2 days of weekend, so can our Histopaque-1077 stored in this refrigerator can be used anymore?

    1 answer
    1. This product ships at ambient temperature and is stable for relatively short periods at room temperature. There is a 1 - 2 week allowance for transit time. A storage temperature excursion of 2 days is not expected to impact the quality or performance of this material.

      Helpful?

  2. Can Histopaque 10771 be utilized to separate tumor cells from monocytes?

    1 answer
    1. Histopaque 10771 is unlikely to be suitable for separating tumor cells from monocytes. It is designed to separate monocytes and lymphocytes from human blood. Unless the density of your specific tumor cells significantly differs from 1.077 g/ml, there is a possibility that tumor cells may be collected within the mononuclear cell band. Alternatives such as Percoll, Percoll Plus, or OptiPrep could be better options.

      Helpful?

  3. If Histopaque-1077 is brought to room temperature, how long can it be left at that temperature before use? Specifically, will leaving it for a few hours cause any issues?

    1 answer
    1. Ficoll Paque has a storage temperature range of 4°C to 30°C for unopened bottles, while opened bottles should be stored at 4°C to 8°C. However, Histopaque can be stored at room temperature for short periods.

      Helpful?

  4. Can we use a ratio of blood to separation media of 4:3 with Histopaque-1077? Also, can Histopaque-1077 be used to dilute the blood up to 1:2 before layering with separation media with HBSS buffer, and then wash the cells too.

    1 answer
    1. Histopaque 10771/H8889 and Ficoll Paque solutions are produced with similar reagents. As Histopaque has a slightly lower density range, yields might be slightly lower. Therefore, it is a mixed bag and yields with Histopaque might be slightly lower. When observing a very high white cell count, dilution is recommended. The standard dilution for peripheral blood is generally 1:2. For bone marrow, a 1:2 or 1:4 dilution are more commonly used. The expectation is that cell recovery should be almost the same.

      Helpful?

  5. Do you have a recommended protocol for purifying PBMCs from larger volumes using Histopaque 1077 in 50 mL tubes instead of 15 mL tubes?

    1 answer
    1. For PBMCs, the catalog numbers for Histopaque 10771, H8889, and 10831 are applicable. The Instructions For Use indicate that a 15 ml centrifuge tube with 3 ml of Histopaque 10771 is recommended. This procedure can also be used for a 50 ml centrifuge tube, considering that the height of both tubes is comparable while their diameter differs. To accommodate a 50 ml centrifuge tube, it is advised to use 15 ml of Histopaque 10771. No alterations are needed for the centrifugation time and washing steps. It is sufficient to wash the isolated cells with isotonic PBS or cell culture media.

      Helpful?

  6. Are Histopaque 1077 and Ficoll Paque pure products? What is the percentage of polysaccharide or polysucrose in Histopaque 1077 and Ficoll Paque?

    1 answer
    1. Both Histopaque and Ficoll Paque are formulated with a combination of polysucrose 400 and sodium diatrizoate. On average, Histopaque and Ficoll Paque solutions contain approximately 5.7% polysucrose and 9.0% sodium diatrizoate. The final density of these solutions is expected to be around 1.077 g/ml for both products with a typical density variation of +/- 0.001%.

      Helpful?

  7. Can histopaque-1077 be used to isolate live tumor cells in suspension from dead cells/cell debris?

    1 answer
    1. Histopaque 10771 is primarily intended for isolating mononuclear cells from human blood and bone marrow. It is also utilized in cell culture to eliminate dying cells from hybridomas. However, the effectiveness of Histopaque 10771 or Histopaque 10831 in purifying live cells from deceased liver cells remains untested. Percoll and OptiPrep are common alternative methods.

      Helpful?

  8. Is Histopaque 10771 the recommended density for isolating or separating PBMCs in llama blood?

    1 answer
    1. Yes, Histopaque 1077 (catalog number 10771) is the recommended density for mammalian cells.

      Helpful?

  9. Will Histopaque 10771 be suitable for isolating CD45-positive lymphocytes from mouse whole blood?

    1 answer
    1. While Histopaque 10771 can be used for isolating mouse mononuclear cells including lymphocytes and monocytes, the formulation may not be optimal. Alternatively, Histopaque 10831 is available, with a density of 1.083 g/ml and Ficoll Paque 1084 with a density of 1.084 g/mL. These formulations are specifically designed for the purification of mononuclear cells in rats, mice, and small mammals.

      Helpful?

  10. What is the efficacy and reliability of using Histopaque®-1077 for separating low-density neutrophils (LDN) and normal-density neutrophils (NDN) from high-density neutrophils?

    1 answer
    1. The Histopaque 1077 procedure is not designed to purify low-density or high-density neutrophils. Instead, Histopaque 10771 is intended for purifying Peripheral Blood Mononuclear Cells (PBMCs). When using Histopaque 10771, it is expected that the collected mononuclear cells would contain 5% or less of neutrophils, likely in the form of low-density neutrophils.

      Helpful?

1–10 of 21 Questions  

Reviews

Active Filters

  1. 1 Ratings-Only Review

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service