Skip to Content
Merck
  • Preparation and evaluation of benzyl methacrylate monoliths for capillary chromatography.

Preparation and evaluation of benzyl methacrylate monoliths for capillary chromatography.

Journal of chromatographic science (2013-02-21)
Ahmad Aqel, Zeid A ALOthman, Kareem Yusuf, A Yacine Badjah-Hadj-Ahmed, Abdulrahman A Alwarthan
ABSTRACT

This paper describes the comprehensive fabrication of monolithic materials for use as stationary phases in capillary liquid chromatography. Several columns were synthesized in the confines of 320 µm i.d. fused-silica capillaries by single-step in situ copolymerization of benzyl methacrylate and ethylene dimethacrylate (EDMA). The polymerization procedure was optimized by varying the reaction time within the range of 0.5-20 h, and by changing the composition contents of the polymeric mixture. The EDMA content showed a predominant influence on the characteristics of the columns and hence, on their chromatographic properties. The optimum value of the thermal initiator corresponded to 5 mg/mL. Changes of the porous, hydrodynamic properties and morphology of the prepared columns were thoroughly investigated and characterized. Different solvents were used as the mobile phase to demonstrate that the resulting monoliths exhibited good permeability and mechanical stability, whereas swelling and shrinking behaviors were observed and discussed. The efficiency and performance toward different sets of analytes were obtained; mixtures of aromatic hydrocarbons and phenolic compounds were successfully separated and evaluated, and adding tetrahydrofuran to the mobile phase showed improvement in both resolution and peak shapes. The characteristics of the columns were also checked in terms of repeatability and reproducibility.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Anthracene, sublimed grade, ≥99%
Supelco
Anthracene, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Supelco
Sodium hydroxide concentrate, 0.1 M NaOH in water (0.1N), Eluent concentrate for IC
Sigma-Aldrich
Naphthalene, 99%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
3-Ethyl-2,4-pentanedione, mixture of tautomers, 98%
Sigma-Aldrich
Naphthalene, suitable for scintillation, ≥99%
Supelco
Tetrahydrofuran, HPLC grade, ≥99.9%, inhibitor-free
Sigma-Aldrich
Tetrahydrofuran, anhydrous, ≥99.9%, inhibitor-free
Supelco
Anthracene, analytical standard
Sigma-Aldrich
Sodium hydroxide solution, BioUltra, for molecular biology, 10 M in H2O
Sigma-Aldrich
2,2′-Azobis(2-methylpropionitrile), purum, ≥98.0% (GC)
Supelco
1-Propanol, analytical standard
Sigma-Aldrich
Anthracene, suitable for scintillation, ≥99.0% (GC)
Supelco
Methanol, analytical standard
Sigma-Aldrich
Sodium hydroxide, BioUltra, for luminescence, ≥98.0% (T), pellets
Sigma-Aldrich
Anthracene, ReagentPlus®, 99%
Sigma-Aldrich
Tetrahydrofuran, anhydrous, contains 250 ppm BHT as inhibitor, ≥99.9%
Sigma-Aldrich
Rhein, technical grade
Supelco
Naphthalene, analytical standard
Sigma-Aldrich
1-Propanol, natural, ≥98%, FG
Sigma-Aldrich
Anthracene, reagent grade, 97%
Supelco
Sodium hydroxide solution, 49-51% in water, eluent for IC
Sigma-Aldrich
2,2′-Azobis(2-methylpropionitrile), 98%
Sigma-Aldrich
Rhein
Supelco
Tetrahydrofuran, Selectophore, ≥99.5%
Supelco
Tetrahydrofuran, analytical standard
Supelco
Tetrahydrofuran, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Sodium hydroxide, ultra dry, powder or crystals, 99.99% trace metals basis
Supelco
Naphthalene, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland