20511
Inlet Liner, colonne remplie, pour Agilent®/HP 5700, 5830/40A, 5880A, 5890A
pkg of 25 ea
Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme
About This Item
Produits recommandés
Conditionnement
pkg of 25 ea
Technique(s)
gas chromatography (GC): suitable
L × D.E. × D.I.
91.5 mm × 3.0 mm × 1.8 mm
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Description générale
The liner is the second most important part of the inlet. It is the centrepiece of the inlet system, basically a glass tube between the septum and the column, where the sample is evaporated and brought into the gas phase. There are three most important parameters one should keep in mind while choosing a liner, firstly liner volume, considering a typical liner has a volume of 900μl, secondly liner treatment, one should always use a deactivated liner, so that the glass does not react with the analytes introduced in the liner, thirdly liner design, different designs are available like straight, tapered, baffled and without glass wool and one should be careful enough while choosing the design such that it is compatible with the desired injection mode.
- Longueur 91,5 mm × D.E. 3 mm × D.I. 1,8 mm.
- Remplace la référence du fabricant: 5080-3782
Application
Inlet liner maybe used for the determination and evaluation of volatile components in food products. The vegetable oil maybe directly placed into the GC inlet liner packed with glass wool and then inserted into the heated inlet of the GC for analysis.
Faites votre choix parmi les versions les plus récentes :
Certificats d'analyse (COA)
Désolés, nous n'avons pas de COA pour ce produit disponible en ligne pour le moment.
Si vous avez besoin d'assistance, veuillez contacter Service Clients
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Life sciences, 168, 65-76 (2016-11-20)
p-tertbutylcalix[4]arene loaded nanoemulsion has been designed, characterized and evaluated for skin decontamination of radionuclides of interest in nuclear and radiological emergencies. Further, nanoemulsion was evaluated for Ex-vivo complexation, skin permeation, interaction and cytodermal toxicity. Ex-vivo skin complexation studies were conducted
Fire Debris Analysis.
Science, 249-253 (2007)
Analysis of vegetable oils for flavor quality by direct gas chromatography.
Journal of the American Oil Chemists' Society, 54 (10), 445-449 (1977)
PloS one, 10(3), e0120672-e0120672 (2015-03-18)
The post-menopausal decrease in estrogen circulating levels results in rapid skin deterioration pointing out to a protective effect exerted by these hormones. The identity of the skin cell type responding to estrogens is unclear as are the cellular and molecular
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique