Accéder au contenu
Merck
Toutes les photos(2)

Key Documents

GE28-9269-78

HiScreen Capto Q

Cytiva 28-9269-78

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
47101511
Nomenclature NACRES :
NA.56

ligand

quaternary amine

Description

Ion Exchanger Type (value)

Conditionnement

pkg of 1 ea

Fabricant/nom de marque

Cytiva 28-9269-78

Paramètres

44 psi

Taille du lit

7.7 mm × 100 mm

Volume du lit

4.7 mL

D.I. de la colonne

7.7 mm

Matrice

highly cross-linked agarose with dextran surface extender

Diamètre moyen

90 μm (d50v)

cleaning

2-14

working range

2-12

Adéquation

suitable for bioprocess medium

Description générale

HiScreen Capto Q is a column packed with a strong anion exchange modern resin, combining speed and capacity. Suitable for process development. The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, because the 10 cm bed height provides sufficient residence time. The results can then serve as a basis for linear process scale-up.

Cytiva′s resin couples a quaternary ammonium (Q) strong anion exchanger to a chemically modified, high-flow agarose matrix. The rigid agarose matrix provides greater particle rigidity without compromising pore size, which allows for high bed volume and purification of viscous samples at high flow rates.High dynamic binding capacity is achieved with a dextran surface extender that coats the agarose matrix. The resin’s high binding-capacity, high flow rate, and low back pressure reduce process cycle times and improve productivity at process scale.

Caractéristiques et avantages

  • Prepacked with Capto Q strong anion exchange chromatography resin.
  • Convenient method optimization and parameter screening because of the 10cm bed height.
  • These columns are easily connected in series to increase bed height to 20 cm.
  • Fast results and minimal consumption of sample and buffer consumption through the small bed volume.
  • BioProcess columns packed with the same chromatography resin and using the same linear fluid velocity can produce scalable, reproducible results.

Stockage et stabilité

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol)

Remarque sur l'analyse

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Informations légales

Capto is a trademark of Cytiva
HiScreen is a trademark of Cytiva

Produit(s) apparenté(s)

Pictogrammes

Flame

Mention d'avertissement

Warning

Mentions de danger

Code de la classe de stockage

3 - Flammable liquids


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique