GE17-0727-20
SOURCE™ 15RPC
Cytiva 17-0727-20, pack of 10 mL
About This Item
Produits recommandés
ligand
matrix surface
Caractéristiques
autoclavable 20 min at 121°C
Conditionnement
pack of 10 mL
Fabricant/nom de marque
Cytiva 17-0727-20
Matrice
polystyrene/divinylbenzene
Taille moy. des particules
15 μm (monosized)
cleaning in place
1-14
working range
1-12
Capacité
~10 mg binding capacity
Adéquation
suitable for bioprocess medium
Description générale
Application
High quality assurance standards in combination with the patented production method, particle structure is consistent both bead-to-bead and batch-to-batch.
A controlled pore size distribution and large specific surface area offer excellent capacity for a wide range of molecules, from small peptides and oligonucleotides up to large Proteins. With full pH range stability, SOURCE™ 15RPC is a strong alternative to silica-based RPC matrices.
SOURCE™ 15RPC is available in a range of different bulk pack sizes for easy scale-up and process development. As member of the BioProcess media range, SOURCE™ 15RPC meets industrial demands with security of supply and comprehensive technical and regulatory support.
Caractéristiques et avantages
- Mono-sized 15 μm rigid beads gives Low back pressures and high flow rates allowing for high productivity.
- Designed for high resolution reversed phase chromatography of Proteins, peptides and oligonucleotides.
- High chemical stability allowing for wide range of working conditions with good resistance to cleaning conditions at high pH
- BioProcess medium supported for industrial applications.
Stockage et stabilité
Remarque sur l'analyse
Informations légales
Mention d'avertissement
Warning
Mentions de danger
Conseils de prudence
Code de la classe de stockage
3 - Flammable liquids
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Articles
“Ghosting” in chromatograms due to poor eluent quality; trace organic impurities concentrate, causing unknown peaks.
“Ghosting” in chromatograms due to poor eluent quality; trace organic impurities concentrate, causing unknown peaks.
“Ghosting” in chromatograms due to poor eluent quality; trace organic impurities concentrate, causing unknown peaks.
“Ghosting” in chromatograms due to poor eluent quality; trace organic impurities concentrate, causing unknown peaks.
Protocoles
In this section the practical aspect of Reverse Phased Chromatography ( RPC) is discussed including media and column selection and eluent selection and preparation.
In this section the practical aspect of Reverse Phased Chromatography ( RPC) is discussed including media and column selection and eluent selection and preparation.
In this section the practical aspect of Reverse Phased Chromatography ( RPC) is discussed including media and column selection and eluent selection and preparation.
In this section the practical aspect of Reverse Phased Chromatography ( RPC) is discussed including media and column selection and eluent selection and preparation.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique