Direkt zum Inhalt
Merck
  • Salt-independent hydrophobic displacement chromatography for antibody purification using cyclodextrin as supermolecular displacer.

Salt-independent hydrophobic displacement chromatography for antibody purification using cyclodextrin as supermolecular displacer.

Journal of chromatography. A (2014-12-03)
Jun Ren, Peng Yao, Jingjing Chen, Lingyun Jia
ZUSAMMENFASSUNG

Hydrophobic interaction chromatography (HIC) offers an orthogonal selectivity to ion exchange chromatography and the combination of the two processes can provide a potential cost-effective alternative to protein A chromatography in industrial antibody purification. However, the application of HIC is limited by its close dependence on high concentrations of kosmotropic salts to achieve desired separation. These salts can cause antibody precipitation and induce the corrosion of manufacturing facilities. Here, we report a new strategy of salt-independent HIC, which can capture antibody at the physiological salt concentration and allow the recovery of bound proteins through cyclodextrin (CD)-based displacement elution. Hydrophobicity-intensified HIC media with different coupling amount of phenyl ligands were prepared and assessed for their antibody binding capacity and selectivity. β-CD was investigated for its supermolecular interaction with phenyl ligands and elution capacity as a displacer. The results clarified a nearly linear correlation between binding capacity of human immunoglobulin G (IgG) and phenyl coupling density in the range of 44-159 μmol/mL. The host-guest interaction between β-CD and the phenyl ligands revealed a modest binding strength (Ka=4.1×10(3) M(-1)), and 15 mM β-CD solution showed a general effectiveness as displacement eluent for these HIC media, with IgG recovery varying with the ligand density. This strategy allowed the direct purification of human IgG from serum with satisfactory purity. The whole procedure of this method, including loading and elution, can be performed under physiological conditions. We expect such a salt-independent mode of HIC could be used as a capture or intermediate step in industrial antibody purification.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Benzoesäure, ACS reagent, ≥99.5%
USP
Benzoesäure, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Benzoesäure, ≥99.5%, FCC, FG
Supelco
Benzoesäure, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Mettler-Toledo Kalibriersubstanz ME 18555, Benzoesäure, analytical standard, (for the calibration of the melting point system), traceable to primary standards (LGC)
Sigma-Aldrich
Benzoesäure, natural, ≥99.5%, FCC, FG
Sigma-Aldrich
Benzoesäure, meets analytical specification of Ph. Eur., BP, USP, FCC, E210, 99.5-100.5% (alkalimetric)
Supelco
Schmelzpunktstandard 121-123°C, analytical standard
Supelco
Benzoesäure, reference material for titrimetry, certified by BAM, >99.5%
Sigma-Aldrich
Benzoesäure, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99.9% (alkalimetric)
Sigma-Aldrich
Benzoesäure, ReagentPlus®, 99%
Supelco
Benzoesäure, Standard for quantitative NMR, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
Benzoesäure, purified by sublimation, ≥99%
Benzoesäure, European Pharmacopoeia (EP) Reference Standard