Direkt zum Inhalt
Merck
  • Electrochemical in situ fabrication of titanium dioxide-nanosheets on a titanium wire as a novel coating for selective solid-phase microextraction.

Electrochemical in situ fabrication of titanium dioxide-nanosheets on a titanium wire as a novel coating for selective solid-phase microextraction.

Journal of chromatography. A (2014-07-20)
Yi Li, Min Zhang, Yaoxia Yang, Xuemei Wang, Xinzhen Du
ZUSAMMENFASSUNG

A novel TiO2-nanosheets coated fiber for solid-phase microextraction (SPME) was fabricated by anodization of Ti wire substrates in ethylene glycol with concentrated NH4F. The in situ fabricated TiO2-nanosheets were densely embedded into Ti substrates with about 1μm long, 300nm wide and 80nm thick. The as-fabricated TiO2-nanosheets coating was employed to extract polycyclic aromatic hydrocarbons, phthalates and ultraviolet (UV) filters in combination with high performance liquid chromatography-UV detection (HPLC-UV). It was found that the TiO2-nanosheets coating exhibited high extraction capability and good selectivity for some UV filters frequently used in cosmetic sunscreen formulations. The main parameters affecting extraction performance were investigated and optimized. Under the optimized conditions, the calibration graphs were linear in the range of 0.1-400μgL(-1). The limits of detection of the proposed method were between 0.026μgL(-1) and 0.089μgL(-1) (S/N=3). The single fiber repeatability varied from 4.50% to 8.76% and the fiber-to-fiber reproducibility ranged from 7.75% to 9.64% for the extraction of spiked water with 50μgL(-1) UV filters (n=5). The SPME-HPLC-UV method was successfully established for the selective preconcentration and sensitive detection of target UV filters from real environmental water samples. Recovery of UV filters spiked at 10μgL(-1) and 25μgL(-1) ranged from 88.8% to 107% and the relative standard deviations were less than 9.8%. Furthermore the in situ growth of the TiO2-nanosheets coating was performed in a highly reproducible manner and the TiO2-nanosheets coated fiber has high mechanical strength, good stability and long service life.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Ethylenglycol, ReagentPlus®, ≥99%
Sigma-Aldrich
Ammoniumfluorid, ACS reagent, ≥98.0%
USP
Ethylenglycol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Ethylenglycol, anhydrous, 99.8%
Sigma-Aldrich
Pyren, 98%
Sigma-Aldrich
Ammoniumfluorid, ≥99.99% trace metals basis
Sigma-Aldrich
Naphthalin, 99%
Sigma-Aldrich
Ethylenglycol, spectrophotometric grade, ≥99%
Sigma-Aldrich
Phenanthren, 98%
Sigma-Aldrich
Anthracen, ReagentPlus®, 99%
Supelco
Ethylenglycol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Anthracen, reagent grade, 97%
Sigma-Aldrich
Pyren, puriss. p.a., for fluorescence, ≥99.0% (GC)
Sigma-Aldrich
2-Ethylhexylsalicylat, 99%
Sigma-Aldrich
Ethylenglycol, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
Ethylenglykol 5 M -Lösung
Sigma-Aldrich
Naphthalin, suitable for scintillation, ≥99%
Supelco
Ethylenglycol, analytical standard
Sigma-Aldrich
Fluoranthen, 98%
Supelco
Naphthalin, analytical standard
Supelco
Pyren, analytical standard
Supelco
Phenanthren, analytical standard, for environmental analysis
Supelco
Octisalat, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Phenanthren, sublimed grade, ≥99.5%
Supelco
Fluoranthen, analytical standard
Supelco
Anthracen, analytical standard
USP
Octisalat, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
2-Ethylhexylsalicylat, ≥99%
Supelco
Naphthalin, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Schmelzpunktstandard 79-81 °C, analytical standard