Polysep™ II 2.0/1.2 µm nominal, Opticap® XL Capsule
pore size 2.0/1.2 μm, Opticap® XL 2, filter diam. 5.7 in. (14.5 cm), cartridge nominal length 2 in. (5 cm)
About This Item
Empfohlene Produkte
Materialien
borosilicate glass fiber (BGF) membrane
mixed cellulose esters (MCE) membrane
polypropylene filter
polypropylene housing
polypropylene support
silicone seal
Qualitätsniveau
Einhaltung gesetzlicher Vorschriften
FDA 21CFR177-182 (all component materials)
Sterilität
non-sterile
Kompatibilität mit Sterilisationsverfahren
autoclavable compatible
Produktlinie
Opticap® XL 2
Leistungsmerkmale
hydrophilic
Hersteller/Markenname
Opticap®
Parameter
1 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
Methode(n)
prefiltration: suitable
Nennlänge Kartusche
2 in. (5 cm)
device L
14.2 cm (5.6 in.)
device size
2 in.
Filterdurchm.
5.7 in. (14.5 cm)
filter filtration area
0.06 m2
Durchm. Einlassanschluss
3/4 in.
inlet to outlet width
14.2 cm (5.6 in.)
Durchm. Auslassanschluss
9/16 in.
Verunreinigungen
≤0.5 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.5 EU/mL bacterial endotoxins (LAL test, sample aqueous extraction)
Matrix
Polysep™ II
pore size
2.0/1.2 μm nominal pore size
2.0/1.2 μm pore size
Fitting
(19 mm (3/4 in.) Sanitary Flange Inlet and 14 mm (9/16 in.) Hose Barb Outlet)
Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich
Allgemeine Beschreibung
Leistungsmerkmale und Vorteile
Verpackung
Angaben zur Herstellung
3 autoclave cycles of Sterilization Method: 30min at 121°C; not in-line steam sterilizable
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21CFR210.3(b)(6).
Hinweis zur Analyse
Sonstige Hinweise
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer first page of Visual Inspection Guide and introduction section of Mixed cellulose esters Tech Brief
- Storage Statement: Please refer Mixed cellulose esters Tech Brief
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Rechtliche Hinweise
Not finding the right product?
Try our Produkt-Auswahlhilfe.
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.